Sony DPP-MS300E Service Manual page 24

Hide thumbs Also See for DPP-MS300E:
Table of Contents

Advertisement

[D/A Output CHROMA Level Adjustment] (DK-40 board)
Mode
VIDEO Input
Signal
Color bar (VIDEO IN)
Measuring point
J1802 (OUTPUT)
Measuring equipment
Oscilloscope
Adjustment part
RV402
Specification value
681 ± 5 mVp-p
Adjustment Procedure:
(1) Adjust RV402 so that the A level (Red) of waveform on the
oscilloscope satisfies the specification value.
(2) Turn off the power switch.
White (100%)
H
Fig. 4-8
[A/D Input Y Level Adjustment] (DK-40 board)
Note: Turn off the power switch once, then turn it on again.
Mode
VIDEO Input
Signal
Color bar (S-VIDEO IN)
Measuring point
CL409
Measuring equipment
Oscilloscope
Adjustment part
RV404
Specification value
1.30 ± 0.01 Vp-p
Adjustment Procedure:
(1) Connect on oscilloscope to the CL409 (from IC407 ^¢ pin
to the point via R478).
(2) Adjust RV404 so that the A level (white) of waveform on
the oscilloscope satisfies the specification value.
White (100%)
H
Fig. 4-9
A
Red
A
4-5
[A/D Input R-Y/B-Y Level Adjustment]
(VI-40, DK-40 board)
Mode
VIDEO Input
Signal
Color bar (S-VIDEO IN)
Measuring point
CL407, 408
Measuring equipment
Oscilloscope
Adjustment parts
RV106, 405
CL407 (R-Y) 1.05 ± 0.01 Vp-p
Specification value
CL408 (B-Y) 1.20 ± 0.01 Vp-p
Adjustment Procedure:
(1) Connect on oscilloscope to the CL408.
(2) Adjust RV106 so that the A level (B-Y) of waveform on the
oscilloscope satisfies the specification value.
Yellow
Fig. 4-10
(3) Connect on oscilloscope to the CL407.
(4) Adjust RV405 so that the A level (R-Y) of waveform on the
oscilloscope satisfies the specification value.
Yellow
Fig. 4-11
Blue
A
Red
A

Advertisement

Table of Contents
loading

Table of Contents