Features And Specifications - IBM eServer 330 xSeries Installation Manual

Hide thumbs Also See for eServer 330 xSeries:
Table of Contents

Advertisement

Features and specifications

The following table provides a summary of the features and specifications for your
server.
Table 1. Features and Specifications.
Microprocessor:
®
®
Intel
Pentium
III
microprocessor with MMX™
technology and SIMD
extensions
133 MHz Front-Side Bus (FSB)
512 KB Level-2 cache
Supports up to two
microprocessors
Memory:
Standard: 256 MB
Maximum: 4 GB
Type: 133 MHz, ECC, SDRAM,
registered DIMMs
Slots: Four dual inline
Drives standard:
Diskette: 1.44 MB
CD-ROM: 24X IDE
Expansion bays:
Two 3.5-inch slim high bays for hard
disk drives
PCI expansion slots:
Two 33 MHz/64-bit
Power supply:
One 200 watt (115-230 V ac)
Video:
S3 Savage4 PRO
Graphics/Video Accelerator
(integrated on system board)
Compatible with SVGA
8 MB SDRAM video memory
2
IBM® xSeries 330: Installation Guide
Size
Height 43.69 mm (1.72 in.)
Depth: 653.29 mm (25.72 in.)
Width: 439.93 mm (17.32 in.)
Weight: approximately 12.7 kg
(28 lb) when fully configured
Integrated functions:
Advanced System Management
(ASM) processor with support for
IBM Remote Supervisor adapter
One Ultra160 SCSI controller
Two 10BASE-T/100BASE-TX
Intel Ethernet controllers with
Wake on LAN
(WOL) support
Two Universal Serial Bus (USB)
ports
Two RS-485 Advanced System
Management processor ports
(one In, one Out)
One serial port
Two cable chaining technology
(C2T) ports (one In, one Out)
Acoustical noise emissions:
Sound power, idling: 6.1 bel
maximum
Sound power, operating: 6.1 bel
maximum
Sound pressure, idling: 47
decibels
Sound pressure, operating: 47
decibels
Environment:
Air temperature:
°
— Server on: 10
to 35° C (50.0°
to 95.0° F). Altitude: 0 to 914
m (2998.7 ft)
— Server on: 10° to 32° C (50.0°
to 89.6° F). Altitude: 914 m
(2998.7 ft.) to 2133 m (6998.0
ft)
— Server off: 10° to 43° C (50.0°
to 109.4° F). Maximum
altitude: 2133 m (6998.0 ft)
Humidity:
— Server on: 8% to 80%
— Server off: 8% to 80%
Heat output:
Approximate heat output in British
thermal units (Btu) per hour
Minimum configuration: 273 Btu
(80 watts)
Maximum configuration: 751 Btu
(220 watts)
Electrical input:
Sine-wave input (50-60 Hz)
required
Input voltage low range:
— Minimum: 100 V ac
— Maximum: 127 V ac
Input voltage high range:
— Minimum: 200 V ac
— Maximum: 240 V ac
Input kilovolt-amperes (kVA)
approximately:
— Minimum: 0.08 kVA
— Maximum: 0.22 kVA

Advertisement

Table of Contents
loading

Table of Contents