Program Utility; 1/Setting Levels - Korg A1 Owner's Manual

Performance signal processor
Table of Contents

Advertisement

3 Program Utility

1/Setting Levels

After completing the
master volume and
threshold level
settings
The Program Utility Mode provides the 3 following (functions:
1. Setting the master volume and threshold level
2. Setting volume pedal position
3. Setting external control functions
Setting the master volume and noise reduction threshold levels (or each program.
1. While EDIT SELECT Is shown on the display, press the PAGE+ key twice.
The Program Utility Menu is shown on the display.
2. Press the "C" double function edit control [LEVEL].
3. Set the noise reduction level by rotating the "C" double function edit control.
Adjust the threshold level according to the respective noise level. When the chain
includes SEND and RETURN, the level of noise reduction for the input signal can be set
for the input jacks and for the RETURN jack. Rotate the "B" double function edit control to
set the threshold level (or input jacks, and the "D" double function edit control for the
threshold level of the RETURN jack. After pressing the various double function edit
controls, you can use the UP/DOWN keys to change the value one unit at a time.
4. Set the master volume by turning the "F" double function edit control.
5. Press the "H" double function edit control [EXIT] to return to the Program
Utility Menu.
The master volume and input signal noise reduction threshold levels can also reset using
the front panel MASTER OUT and THRESHOLD level controls. These levels are stored
individually for each program.