Important Safety Information - MHSC PARLOR VENT-FREE PL20 Installation And Operating Instructions Manual

Parlor vent-free fireplace system
Table of Contents

Advertisement

IMPORTANT SAFETY INFORMATION

INSTALLER
Please leave these instructions with the appliance.
Any change to this heater or its controls can be dangerous.
Improper installation or use of the heater can cause serious injury or
death from fire, burns, explosion or carbon monoxide poisoning.
Do not allow fans to blow directly into the fireplace. Avoid any drafts that
alter burner flame patterns.
Do not use a blower insert, heat exchanger insert or other accessory,
not approved for use with this heater where applicable.
1. Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies.
. Children and adults should be alerted to the hazard
of high surface temperature and should stay away
to avoid burns or clothing ignition.
3. Young children should be carefully supervised when
they are in the same room with the appliance.
4. Do not place clothing or other flammable material
on or near the appliance.
5. Any safety screen or guard removed for servicing
an appliance, must be replaced prior to operating
the heater.
6. Installation and repair should be done by a qualified
service person.
7. To prevent malfunction and/or sooting, an unvented
gas heater should be cleaned before use and at
least annually by a professional service person.
More frequent cleaning may be required due to
excessive lint from carpeting, bedding materials,
etc. It is imperative that control compartments,
burners and circulating air passageways be kept
clean.
8. CARBON MONOXIDE POISONING: Early signs of
carbon monoxide poisoning are similar to the flu with
headaches, dizziness and/or nausea. If you have these
signs, obtain fresh air immediately. Have the heater
serviced as it may not be operating properly.
9. The installation must conform with local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.l/NFPA54.
10. This unit complies with ANSI Z1.11.b-008 Unvented
Heaters.
11. Do not install the heaters in a bathroom or bedroom.
1. Correct installation of the ceramic fiber logs, proper
location of the heater, and annual cleaning are neces-
sary to avoid potential problems with sooting. Sooting,
resulting from improper installation or operation, can
settle on surfaces outside the fireplace. Refer to log
placement instructions for proper installation.
90D0093
OWNER
Please retain these instructions for future reference.
13. Avoid any drafts that alter burner flame patterns. Do not
allow fans to blow directly into fireplace. Do not place
a blower inside burn area of firebox. Ceiling fans may
create drafts that alter burner flame patterns. Sooting
and improper burning will occur.
14. Caution: Candles, incense, oil lamps, etc. produce
combustion byproducts including soot. Vent-free appli-
ances will not filter or clean soot produced by these
types of products. In addition, the smoke and/or aro-
matics (scents) may be reburnt in the vent-free appli-
ance which can produce odors. It is recommended to
minimize the use of candles, incense, etc. while the
vent-free appliance is in operation.
15. This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed. Provi-
sions for adequate combustion and ventilation air must
be provided. Refer to Page 8.
16. Keep room area clear and free from combustible
materials, gasoline and other flammable vapors and
liquids.
17. Unvented gas heaters are a supplemental zone heater.
They are not intended to be the primary heating appli-
ance.
18. Unvented gas heaters emit moisture into the living
area. In most homes of average construction, this
does not pose a problem. In houses of extremely
tight construction, additional mechanical ventilation is
recommended.
19. During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain
oils, films or bonding agents. These chemicals are not
harmful but may produce annoying smoke and smells
as they are burned off during the initial operation of the
appliance; possibly causing headaches or eye or lung
irritation. This is a normal and temporary occurrence.
The initial break-in operation should last two to three
hours with the burner at the highest setting. Provide
maximum ventilation by opening windows or doors to
allow odors to dissipate. Any odors remaining after this
initial break-in period will be slight and will disappear
with continued use.
Parlor Vent Free Fireplace
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pl20nvPl20pv

Table of Contents