Natural Gas; Propane/Lp - Monessen Hearth DEB30 Installation And Operating Instructions Manual

Unvented gas log heater or vented decorative appliance
Table of Contents

Advertisement

PRODUCT FEATURES

NATURAL GAS

NOTE: An external regulator is required to reduce supply pressure to a maximum of 10
natural gas systems operating at higher pressure.
Manual Pressure
Regulator Pressure: Setting: 3.0" w.c.
Gas Inlet Pressure: Max. 10
Min. 5" w.c.
Model Number
DEB20NM
DEB24NM
DEB30NM
DEB20NV
DEB24NV
DEB30NV
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Manual Pressure
Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Max. 13" w.c.
Min. 11" w.c.
Model Number
DEB20PM
DEB24PM
DEB30PM
DEB20PV
DEB24 PV
DEB30PV
6
SPECIFICATIONS
AND
Milli-Volt Pressure
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
1
/
" w.c.
Gas Inlet Pressure: 10
2
Control
MANUAL
MANUAL
MANUAL
MILLI-VOLT
MILLI-VOLT
MILLI-VOLT
Milli-Volt Pressure
Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Max. 13" w.c.
Control
MANUAL
MANUAL
MANUAL
MILLI-VOLT
MILLI-VOLT
MILLI-VOLT
1
/
" w.c.
2
Min. 5" w.c.
Gas Rate
Max BTU/Hr
28,000
38,000
38,000
28,000
38,000
38,000
Min. 11" w.c.
Gas Rate
Max BTU/Hr
28,000
38,000
38,000
28,000
38,000
38,000
1
/
" W.C. on
2
Min BTU/Hr
18,000
20,000
20,000
18,000
25,000
25,000
Min BTU/Hr
18,000
20,000
20,000
20,000
30,000
30,000
44D0060