GE DPSE592EA0 Technical Service Manual page 31

Wizard 7.0 cubic foot super capacity dryer
Hide thumbs Also See for DPSE592EA0:
Table of Contents

Advertisement

L3 Dryer - Gas Model
Dryer
Proper voltage to
No
Dryer.
Yes
Enter field service
mode (disconnect/
reconnect power, then
press and hold Start
and Cotton buttons).
Test
Unit will start
Mode.
and run. Continue to
hold buttons until
diagnostics mode is
entered.
House fuse, breaker,
wall outlet problem.
DSSD output displays
Fd, GA, and EEPROM
version number.
Check error codes.
Press Mixed Loads
button - DSSD output
displays error codes for
existing errors.
Press Stop to exit field
service mode.
Sensor Rods, Open
S0
Circuit, Normal
Sensor Rods, Circuit
E2
Problem, Shorted
Sn
Motor Switches ON
1n
Igniter Turns ON
Ultra Care Relay
2n
Turns ON
dO
Door Open
dC
Door Closed
– 29 –
Touch rods
with hand for
SS
No Fault, Rods OK.
20 seconds.
Touch rods
Capacitor Leaks -
with hand for
SS
Replace capacitor.
20 seconds.
Not Connected to
E2
Circuit - Check
connection.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dpse592ga0Dncd450ea0Dncd450ga0

Table of Contents