Troubleshooting Flowcharts - GE DPSE592EA0 Technical Service Manual

Wizard 7.0 cubic foot super capacity dryer
Hide thumbs Also See for DPSE592EA0:
Table of Contents

Advertisement

L3 Dryer - Electric Model
Dryer
Proper voltage to
No
Dryer.
Yes
Enter field service
mode (disconnect/
reconnect power, then
press and hold Start
and Cotton buttons).
Test
Unit will start
Mode.
and run. Continue to
hold buttons until
diagnostics mode is
entered.

Troubleshooting Flowcharts

House fuse, breaker,
wall outlet problem.
DSSD output displays
Fd, EL, and EEPROM
version number.
Check error codes.
Press Mixed Loads
button - DSSD output
displays error codes for
existing errors.
Press Stop to exit field
service mode.
E0
Thermistor, No Error.
Thermistor Error or
E1
Board.
Sensor Rods, Open
S0
Circuit, Normal
Sensor Rods, Circuit
E2
Problem, Shorted
Sn
Motor Switches ON
Heater 1 Turns
H1
ON, Outer
Heater 2 Turns ON
H2
(1 OFF), Inner
dO
Door Open
dC
Door Closed
– 28 –
Touch rods
with hand for
SS
No Fault, Rods OK.
20 seconds.
Touch rods
Capacitor Leaks -
with hand for
SS
Replace capacitor.
20 seconds.
Not Connected to
E2
Circuit - Check
connection.