SMART MANAGER / CENTRAL REMOTE CONTROL Installation Manual Model name: BMS-SM1280HTLUL (SMART MANAGER) BMS-CM1281TLUL (CENTRAL REMOTE CONTROL) • Save These Instructions! ENGLISH...
Smart Manager / Central Remote Control • Thank you very much for purchasing this TOSHIBA / Carrier Smart Manager / Central Remote Control. • Please read this manual carefully beforehand for proper installation of the Smart Manager / Central Remote Control.
Installation Manual Smart Manager / Central Remote Control Precautions for safety • Read these “Precautions for Safety” carefully before installation. • The precautions described below include important items regarding safety. Observe them without fail. Understand the following details (indications and symbols) before reading the body text, and follow the instructions.
Smart Manager / Central Remote Control Specifications Part name Central Controller Power Unit Model name BMS-SM1280HTLUL / BMS-CM1281TLUL Power supply 120 VAC, 60 Hz Use bundled power unit. Power consumption 6 W (SM1280) / 4 W (CM1281) Up to 128 units Indoor unit —...
Installation Manual Smart Manager / Central Remote Control Before installation Confirm all the parts on the list below are supplied. Part name Part name Quantity Remarks Central Controller Power unit 2 languages Installation Manual English, French. Owner’s Manual Central Remote Control has no Network Configuration Network Configuration Guide Guide CD-R...
Installation Manual Smart Manager / Central Remote Control Installation of the smart manager / central remote control CAUTION • Do not twist communication wires and input / output wires with power wires or bundle them together with power wires in a metal tube. Doing so may cause malfunction. •...
Page 7
Installation Manual Smart Manager / Central Remote Control Power unit installation method and orientation There are five installation methods for this power unit as shown below: surface mount and wall mounts. Use the attached screws. No good REQUIREMENT Do not install the unit in any of the following places. •...
Page 8
Installation Manual Smart Manager / Central Remote Control Combining the central controller and power unit You can combine the central controller and power unit using the supplied brackets as follows in order to control them as one unit Power unit Bracket Panel Combination method...
Installation Manual Smart Manager / Central Remote Control Connection of power cables / earth wires / communication cables Connect power cables, communication cables, and earth wires to the specified terminals on the terminal block. REQUIREMENT Attach a ring tongue terminal to the end of each wire except those for digital input and output. TCC-LINK U1 and U2 The power terminals on the central have no polarity.
Page 10
Installation Manual Smart Manager / Central Remote Control Length of stripped power cable Length of stripped TCC-LINK Length of stripped RS-485 Length of stripped digital Input / communication cable communication cable Output communication wire 1.38" (35) 1.38" (35) 1.38" (35) 0.24"...
Page 11
Installation Manual Smart Manager / Central Remote Control A connection example of Smart Manager system wiring is shown below. Connection of wiring Here is shown a connection example of Smart Manager wiring to indoor units, Energy monitoring relay interface, Digital Input / Output relay interface and client PC. Termination setting •...
Installation Manual Smart Manager / Central Remote Control Switches for setting The switches for settings are equipped on the back of the panel. Must be set to OFF Normal All stop 2 Normal All stop 2 Synchronization of All stop input 2 1, 2, 3 Must be set to OFF Setting Zone data switching...
Page 13
Installation Manual Smart Manager / Central Remote Control <DS23> Factory setting: All OFF <1> Smart Manager / Central Remote Control main / sub selection DS23 OFF: Main 2 3 4 5 6 7 8 ON: Sub Normally, this bit is set to OFF. When two Smart Manager / Central Remote Control units are used as a main unit and a sub unit with the same mode setting, set this bit to OFF (Main) for one unit and to ON (Sub) for the other unit.
Page 14
Installation Manual Smart Manager / Central Remote Control Factory setting: All OFF <DS24> DS24 2 3 4 5 6 7 8 <1> to <4> Always OFF Always set this bit to OFF. <5> Control group Selection line OFF: LINE 1 ON: LINE 2 * Set a line number for which the control group selection is used.
Page 15
Installation Manual Smart Manager / Central Remote Control <DS25> Factory setting: All OFF <1> Always OFF DS25 • Always set this bit to OFF. 2 3 4 <2> Synchronization of zone setting data OFF: With synchronization ON: Without synchronization This bit specifies whether to perform synchronous communication of zone setting data between Smart Manager / Central Remote Controls.
Installation Manual Smart Manager / Central Remote Control Central control address (group number) setting • Central control addresses must be assigned to all air conditioners to be controlled. • Under the control of the Smart Manager / Central Remote Control, central control address equals group number. <Preparations for central control address (group number) setting>...
Page 17
Installation Manual Smart Manager / Central Remote Control B Manual setting Set central control addresses (group numbers) manually from the Smart Manager / Central Remote Control. (1) Press the button and ZONE button simultaneously for at least 4 seconds. (CODE No. C1 flashes.) (2) Check CODE No.
Page 18
Installation Manual Smart Manager / Central Remote Control <Correcting duplicate address> Correct the duplicate address detected through the check using the following procedure. (1) When the duplicate address check has been completed, select CODE No. C1 with the SET TEMP. button.
Installation Manual Smart Manager / Central Remote Control Mode setting for smart manager / central remote control Operation mode You can switch the functional mode of the smart manager / central remote control between the central control mode and remote control mode. The mode is switched with the dip switch DS23-<6>. OFF side: Central control mode This Smart Manager / Central Remote Control is used as a central control unit.
Installation Manual Smart Manager / Central Remote Control Zone setting What is zone? • A zone is a control unit consisting of a combination of any indoor units and the settings of indoor units in a zone can be configured collectively. •...
Installation Manual Smart Manager / Central Remote Control Changing return-back time / temperature settings What is return-back? When the return-back function is activated, the temperature setting exceeding the return-back temperature will automatically be adjusted to the return-back temperature after a certain period of time to prevent extremely high / low temperature setting.
Installation Manual Smart Manager / Central Remote Control Test run <Conducting a Test Run for the Smart Manager / Central Remote Control> • A test run is necessary to confirm that the Smart Manager / Central Remote Control has recognized air conditioner units after the central control address setting.
Page 23
Installation Manual Smart Manager / Central Remote Control...
Need help?
Do you have a question about the BMS-CM1281TLUL and is the answer not in the manual?
Questions and answers