Technical Information
6.3
Displayed Messages
BREW UNIT BLOCKED
EXPEL AIR
FILL COFFEE BEANS
BREW UNIT MISSING
DESCALING
WASTE UNIT MISSING
Table 6-3: Displayed Messages (continued on Table 6-4)
Displayed Message
The brew unit is dirty.
The brew unit is blocked.
The brew unit is Jammed.
• Clean / inspect brew unit / check drives
Air is present with the water system –
• Perform "Expel Air" procedure.
The bean container is empty OR
The grinder may be jammed.
• Add coffee beans to the beans
• Clean the conical grinder (top of grinder)
Brew unit is not installed OR
Not installed correctly.
• Reinstall the brew unit
• Check brew unit present switch
• Perform the Descale Procedure.
Waste unit is not installed
• Re-install the waste unit
• Check magnet on rear of waste unit
• Check brew unit present switch
96
CVA615 Coffee System
Information
container.