Dimensions and Installation Information (in inches)
Front & back clearance requirements: A 7" clearance is
recommended with a minimum of 5-1/2" air space between any
object and the front and back of the water heater and 7" on each
side. Clearance is needed to allow for removal of the front and back
covers in the event service is needed.
Top filter removal clearance
requirements: A minimum 6" clearance is
required at the top of the water heater to
pull the filter up and remove it for cleaning.
It is critical that the hot and cold water
plumbing and the electrical connections do
not interfere with the removal of the filter.
Condensate drain required: A primary
drain pipe must be installed at the top right
side of the water heater. The primary drain
is intended to carry all condensate away.
For answers to your Monogram,
GE Profile
®
or GE
®
appliance questions, visit our website
at geappliances.com or call GE Answer Center
service, 800.626.2000.
®
Water Supply Connections: Refer to the illustration below for suggested
typical installation. The installation of unions or flexible copper connectors
is recommended on the hot and cold water connections so that the water
heater may be easily disconnected for servicing if necessary. The HOT and
COLD water connections are clearly marked and are 3/4" NPT on all models.
Note: Install a shut-off valve in the cold water line near the water heater.
This will enable easier service or maintenance of the unit later.
IMPORTANT: Do not apply heat to the HOT or COLD water connections.
If sweat connections are used, sweat tubing to adapter before fitting the
adapter to the cold water connections on heater. Any heat applied to the
hot or cold water connection will permanently damage the dip tube.
Above illustration intended for dimensional reference only.