Sharp LC-13B2UA Service Manual page 21

Hide thumbs Also See for LC-13B2UA:
Table of Contents

Advertisement

Page
Items
LCD controller setup (PAL) / Closed caption setup [continued]
17
PAL 06
PAL 07
PAL 08
PAL 09
PAL 0A
PAL 10
PAL 11
PAL 12
PAL 13
PAL E0
PAL E1
PAL F0
PAL F1
PAL F2
PAL F3
PAL F4
PAL F5
PAL F6
PAL F7
PAL 14
CLOSED CAPTION
CCD ISO
AIR SERCH
Grey level · COM setup
18
V255
V255 BIAS
V235
V235 BIAS
V176
V176 BIAS
V112
V112 BIAS
V64
V64 BIAS
V32
V32 BIAS
19
V21
V21 BIAS
V17
V17 BIAS
V7
V7 BIAS
V0
V0 BIAS
VGL ADJ
VGL COM
COM
G/A READDATA
G/A READDATA
3-dimension setup / Synchronization judgment setup
20
3D Y/C
3D Y/C DATA
3D Y/C DATA
LSYNC
HSYNC
AVSYNC
VPC FP20H
VPC FP21H
VPC FP13H
MSP DEMO200H
L ERROR WAIT
L ERROR H TIME
VPC I
2
C 20H
Mode setup in power-off time
21
DENKA PORT
DENKA TESTP
DENKA TESTP2
REMOCON CODE
Initial settings
Descriptions
13
Horizontal display position
18
Vertical display position
O2
UV data phase delay
4C
Panel clock adjustment
4A
Upper and lower mask position of display screen
80
Test pattern display
00
Test pattern data
00
Horizontal display mask position (left)
00
Horizontal display mask position (right)
00
FIFO TEST
03
Reverse of sinchronized polarity
07
OFL terminal action setup
00
Inverter frequency setup
00
Inverter duty setup
BD
Light control frequency setup lower level
00
Light control frequency setup upper level
00
Light control PWM setup lower level
00
Light control PWM setup upper level
00
Phase of OFL1/2
02
System clock setup
15
CLOSED CAPTION THRESH LEVEL
16
CLOSED CAPTION phase setup
1.600
Judging frequency of last synchronization in
AIR CH SEARCH mode
255
Grey level power source reference voltage
127
Grey level power source reference voltage
226
Grey level power source reference voltage
127
Grey level power source reference voltage
133
Grey level power source reference voltage
150
Grey level power source reference voltage
99
Grey level power source reference voltage
170
Grey level power source reference voltage
68
Grey level power source reference voltage
40
Grey level power source reference voltage
62
Grey level power source reference voltage
45
Grey level power source reference voltage
46
Grey level power source reference voltage
50
Grey level power source reference voltage
45
Grey level power source reference voltage
55
Grey level power source reference voltage
27
Grey level power source reference voltage
65
Grey level power source reference voltage
0
Grey level power source reference voltage
80
Grey level power source reference voltage
27
VGL bias setup
215
VGL COM setup
181
COM amplitude setup
00 00
Controller READ DATA setup
WAIT
READ execute
0
3-dimension ON/OFF setup
0
3-dimension Y/C data WRITE and READ
WAIT
WRITE and READ execute
625
Limit value of sychronization judgment (TV)
655
Limit value of sychronization judgment (TV)
5000
Limit value of sychronization judgment
(External input)
Data 0000 VPC data READ value
Data 0000 VPC data READ value
Data 0000 VPC data READ value
Data 0000 MSP data READ value
15s
Lamp error detection WAIT time
1.0s
Lamp error detection time
24
Synchronization control setup
OFF
Mode setup in power-off time
00
Mode setup in power-off time
30ms
Mode setup in power-off time
000
Display codes of receiving remote controller
21
Adjustments or descriptions of change
Change value to "138"
Change value to "103"
Change value to "72"
Change value to "49"
Change value to "29"
LC-13B2UA