No.
Adjustment Items
16
Adjustment of
COMPO CB offset
and CR offset
17
Adjustment of
COMPO white
balance
18
Adjustment of
sRGB white
balance
Teaching intervals:
Brightness adjustable direction: Brightness up by increasing the setting (to be checked)
Adjusting points:
Adjustable colors:
(2) Color irregularity correction (adjustment)
C50 conditions setup (
Correction procedure settings
Gradation 7:
Gradation 6:
Gradation 5:
Gradation 4:
Gradation 3:
Gradation 2:
Gradation 1:
Gradation 0:
For the model in question, select the name entered in (2) to start the color irregularity correction. If the
set has its optical characteristics rather different from the standard ones or if the set has some color
irregularity lines missing, do the teaching for that set in particular. Use its specified correction coeffi-
cients in making the adjustment.
Adjustment Conditions
1. Feed the Y-0% brightness, Cb and
Cr 0% white pattern color difference
signal (480I).
2. Select the following group and sub-
ject.
Group: COMPO
Subject: AUTO
1. Feed the DTV monoscope pattern
signal.
2. Select the following group and sub-
jects.
Group: DLP
Subjects: C-R1-BLK, C-B1-BLK
1. Feed the RGB 50% gray pattern
signal.
2. Select the following group and sub-
jects.
Group: OUTPUT1
Subjects: S-R1-BLK, S-R1-GAIN, S-
G1-BLK, S-G1-GAIN, S-B1-BLK, S-
B1-GAIN
3. Have the BM-5 brightness meter and
the standard white board at hand.
18
Three dimension (to be checked)
Gradation 4 (to be checked)
Gradation 5 (to be checked)
Gradation 6 (to be checked)
Other gradations not to be checked
R, G and B adjustable (to be checked)
)
2. Lower-gradation correction value to be used.
0. Correction with correction coefficient.
0. Correction with correction coefficient.
0. Correction with correction coefficient.
1. Upper-gradation correction value to be used.
1. Upper-gradation correction value to be used.
4. Initial value to be used.
4. Initial value to be used.
Adjustment Procedures
1. Feed the signal. Using the set's con-
trol switch or the remote controller
button, select the subject AUTO. The
setting will adjust itself.
1. Using the set's control switch or the
remote controller button, adjust the
settings to have the same white bal-
ance as on the standard monitor.
1. Make the S-R1-BLK setting the same
as the R1-BLK one.
Make the S-G1-BLK setting the same
as the R1-BLK one.
Make the S-B1-BLK setting the same
as the R1-BLK one.
Make the S-R1-GAIN setting the
same as the R1-GAIN one.
2. Adjust the S-B1-GAIN and S-G1-
GAIN settings so that the chroma-
ticity on the brightness meter should
be as follows.
x: .313±7/1000
y: .350±10/1000