Operation in each TEST mode

1. AUTO1 Mode

• When the STOP button is pressed while the AUTO1 menu appears or during automatic adjustment, the mode changes to the TEST mode
stop state. At this time the adjustment value is not output.
• Be sure to adjust, using the specified disc MMD-212.
At this time release the EEPROM (IC402) protection. (Refer to EEPROM write procedure.)
• Adjustment NG; Adjustment item out of range, focus ON failure, and adjustment error
• When the PLAY button is pressed while ADJ. OK is displayed, AUTO2 is executed.

2. AUTO2 Mode

• When the STOP button is pressed while the AUTO2 menu appears or during automatic adjustment, the mode changes to the TEST mode
stop state. At this time the adjustment value is not output.
• Adjustment NG; Adjustment item out of range, and adjustment error.
• When the PLAY button is pressed while ADJ. OK is displayed,TEST_PLAY is executed.

3. MANUAL1 Mode

• Adjustment item to be made in AUTO1 mode is performed manually.
• When the VOL UP button is pressed during adjustment, the setting increases, and the new setting is output.
• If the VOL DOWN button is pressed during adjustment, the setting decreases and the new setting is output.
• If the VOL UP/DOWN button is held down, the setting changes continuously with 100 ms cycle.
*In this operation, the setting change is performed for each digit. The digit is changed by pressing the MODE button.
• If the setting is within the allowable range, the RANDOM display lights.
• When the STOP button is pressed during MANUAL1 MENU or measurement or adjustment, the state is changed to the TEST mode stop
state.
4. MANUAL2 Mode
• Adjustment item to be made in AUTO2 mode is performed manually.
• When the VOL UP button is pressed during adjustment, the setting increases, and the new setting is output.
• If the VOL DOWN button is pressed during adjustment, the setting decreases and the new setting is output.
• If the VOL UP/DOWN button is held down, the setting changes continuously with 100 ms cycle.
*In this operation, the setting change is performed for each digit. The digit is changed by pressing the MODE button.
• If the setting is within the allowable range, the RANDOM display lights.
• When the STOP button is pressed during MANUAL2 MENU or measurement or adjustment, the state is changed to the TEST mode stop
state.
• When the PLAY button is pressed in B-ATT set state, the mode is changed to the continuous playback mode.
• As for operation during continuous playback refer to "TEST-PLAY mode explanation".
5. TEST-PLAY Mode
• When the STOP button is pressed while the TEST-PLAY menu appears, or in TEST-PLAY or continuous playback mode, the mode
changes to the TEST mode stop state.
• When the PLAY button is pressed while the TEST-PLAY menu appears,continuous playback is initiated from the current pickup position.
• Whenever the DISP button is pressed in the TEST-PLAY menu, the target address changes as follows.
0032 — 03C0 — 0700 — 08A0 — 0950— 0032 —
When the PLAY button is pressed while a target address is displayed, continuous playback is performed after searching that address.
• Each time the MODE button is pressed while the TEST-PLAY mode target address is displayed, the digit which is changed by pressing the
SKIP UP/DOWN button is changed as follows.
0032 — 0032 — 0032 — 0032 —
• When the SKIP UP button is pressed in the TEST-PLAY mode target address is displayed, the digit of address specified by the MODE
button is set to +1h. (0 to F)
• When the SKIP DOWN button is pressed in the TEST-PLAY mode target address is displayed, the digit of address specified by the MODE
button is set to -1h. (0 to F)
* When the SKIP UP/DOWN button is held down, the setting changes continuously, one cycle being 100 ms.
• When the BASS button is pressed in the continuous playback mode, the number of jump lines changes as follows.
1 — 10 — 384 — 1
* After the number of jump lines is indicated for one second, the address indication is restored.
• When the SKIP UP button is pressed in the continuous playback mode, the specified number of lines is jumped in the FWD direction.
• When the SKIP DOWN button is pressed in the continuous playback mode, the specified number of lines is jumped in the REV direction.
* When the SKIP UP/DOWN button is held down, jump is repeated every approx. 100 ms.
•Whenever the DISP button is pressed in the continuous playback mode, the indication changes as follows.
* Pre-mastered disc
Continuous playback (SUBQ address indication)
Continuous playback (C1 error indication)
Continuous playback (SUBQ address indication)
* Recordabl disk
Continuous playback (ADIP address indication)
Continuous playback (C1 error indication)
Continuous playback (ADIP error indication)
Continuous playback (ADIP address indication)
|
|
|
|
|
[ S Q
]
[ C E
]
[ S Q
]
[ A P
]
[ C E
]
[ A E
]
[ A P
]
– 13 –
MD-MT831H/W
[
T R _ ]