Sanyo PLC-XTC50L Service Manual page 68

Hide thumbs Also See for PLC-XTC50L:
Table of Contents

Advertisement

Electrical Adjustment
Grp / No.
Item
8
Cooling Time
10
Temp Error Cooling Time
11
OnStart Cooling Start Threshold
12
After shutdown cooling
256
Fan Lamp Voltage Down Setting
0
Lamp Voltage
1
Lamp Vol Threshold
2
Fan1 Speed Gain
257
Fan Setting at Dimmer
0
Dimmer Average Check Period
258
Fan Control Range Setting (for Lamp2)
0
High Fan4 Min (LAMP2)
1
High Fan4 Max (LAMP2)
2
High Fan5 Min (LAMP2)
3
High Fan5 Max (LAMP2)
4
Normal Fan4 Min (LAMP2)
5
Normal Fan4 Max (LAMP2)
6
Normal Fan5 Min (LAMP2)
7
Normal Fan5 Max (LAMP2)
8
Eco Fan4 Min (LAMP2)
9
Eco Fan4 Max (LAMP2)
10
Eco Fan5 Min (LAMP2)
11
Eco Fan5 Max (LAMP2)
259
Fan Air Pressure Setting
0
Press Source Range Low
1
Press Source Range High
Press Fan Add Range High(lamp
2
in)
Press Fan Add Range Low(lamp
3
in)
Press Fan Add Range High(no
4
lamp in)
Press Fan Add Range Low(no
5
lamp in)
260
Auto Calibration (Common)
0
Execute Calibration
1
Loop Count
2
Auto Status
3
AutoWait
4
CHECK - Tolerance
5
Time out wait
261
Auto Calibration (RGB)
0
OFFSET AREA H START
1
OFFSET AREA V START
2
GAIN AREA H START
3
GAIN AREA V START
4
Image AREA H WIDTH
5
Image AREA V HEIGHT
6
OFFSET Target
7
OFFSET Tolerance
8
GAIN Target
9
GAIN Tolerance
10
Image Level Tolerance
262
Auto Calibration (CVBS/SVIDEO) PW392-AFE MDL <10bits>
0
Y Image Area Start X
1
Y Image Area Start Y
6
Image Area H WIDTH
7
Image Area V HEIGHT
8
Y Target Level
11
Gain Tolerance
Function
Cooling Time Setting (x30 sec.) 1: 30 3: 90 15: 450
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
Cooling Operation after Shut Down (0: No, 1: Yes)
Current Lamp Voltage (0.1V) (Read only)
Threshold Voltage (0.1V)
Fan Speed Ad Gain (0.1V)
Dimmer Average Check Period (sec.)
0: 10, 1: 30, 2: 60, 3: 90......10:300
Fan Spinning (Min/Max) (rpm)
Pressure Sensor Control Range (AD)
Add Spinning (Lamp Intake fan)
Add Spinning (without Lamp Intake fan)
Execute Calibration when the Value is changed to 1. (For PC
White 100%)
Max Times of Calibration
Calibration Log (Read only)
0: Calibration End Correctly 1: On Adjusting 9: Calibration
Error
Waiting time
Tolerance of Offset
Wait Time until Time out [sec.]
PW392-AFE MDL <10bits>
Black Level Acq. Area H Start
Black Level Acq. Area V Start
White Level Acq. Area H Start
White Level Acq. Area V Start
Black/White Level Area Width
Black/White Level Area Height
Black Level Adj target
Black Level Adj telerance
White Level Adj target
White Level Adj telerance
Acq. Image Level Adj Tolerance
Y Image Area H Start
Y Image Area V Start
Image Level Acq. Width
Image Level Acq. Height
Y Level Adj target
Level Adj Tolerance
Range
1-15
1-15
0-100
0-1
0-255
30-90
0-1500
0-10
0000 - 9990
5200
0000 - 9990
5200
0000 - 9990
3256
0000 - 9990
3256
0000 - 9990
4424
0000 - 9990
4424
0000 - 9990
2880
0000 - 9990
2880
0000 - 9990
3640
0000 - 9990
3640
0000 - 9990
2504
0000 - 9990
2504
0-1024
0-1024
0 - 5000
0 - 5000
0 - 5000
0 - 5000
0 - 1
1 - 30
0 / 1 / 9
1 - 20
1 - 255
1 - 255
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 1023
1 - 1023
0 - 1023
1 - 1023
1 - 255
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 1023
1 - 255
-68-
Initial
Note
3
3
60
1
---
30
0
1
3256
5200
5200
3256
5600
5600
5200
3256
3256
5200
3656
3656
2880
4424
4424
2880
4824
4824
4424
2880
2880
4424
3280
3280
2504
3640
3640
2504
4040
4040
3640
2504
2504
3640
2904
2904
645
825
1082
2704
720
1432
* Auto calibration
0
8
0
3
4
20
975
500
25
500
13
9
20
1
955
1
8
20
200
8
9
875
1

Advertisement

Table of Contents
loading

Table of Contents