Electrical Adjustment
Grp / No.
Item
50
Warning_Log Reset
235
Shutter
0
PRE_MOTION
1
CMP_TRM
2
OUT_DLY_TRM
3
CMP_CHK_CNT
4
OPEN_DLY
5
CLOSE_DLY
6
Position Check Time
236
Lamp changer
0
Mirror Adjust Mode
1
Lamp Mode Lamp1
2
Lamp Mode Lamp2
10
Lamp1/Lamp2 Change Time
240
Flow Calibration
0
Flow Calibration Exe
1
Flow Calibration Error Log
2
Clog Check Enable
241
Flow Ideal Data
0
Flow Ideal Data 1
1
Flow Ideal Data 2
2
Flow Ideal Data 3
3
Flow Ideal Data 4
4
Flow Ideal Data 5
5
Flow Ideal Data 6
6
Flow Ideal Data 7
7
Flow Ideal Data 8
242
Flow Calib. Fan Duty
0
Flow Calib Fan Duty 1
1
Flow Calib Fan Duty 2
2
Flow Calib Fan Duty 3
3
Flow Calib Fan Duty 4
4
Flow Calib Fan Duty 5
5
Flow Calib Fan Duty 6
6
Flow Calib Fan Duty 7
7
Flow Calib Fan Duty 8
243
Flow Calib Effective Difference
0
Flow Calib Effective Diff 1
1
Flow Calib Effective Diff 2
2
Flow Calib Effective Diff 3
3
Flow Calib Effective Diff 4
4
Flow Calib Effective Diff 5
5
Flow Calib Effective Diff 6
6
Flow Calib Effective Diff 7
7
Flow Calib Effective Diff 8
244
Flow Clog Threshold
0
Flow Clog Threshold 1
1
Flow Clog Threshold 2
2
Flow Clog Threshold 3
3
Flow Clog Threshold 4
4
Flow Clog Threshold 5
Function
Log is cleared when the value is set to 10.
Shutter Warm - up Operation (0: Yes, 1: No)
Chattering Detecting Term
Output Term
Count of Information Sync
Open Output Delay
Close Output Delay
Position Check Time
0: Normal, 1: Lamp1 Adj, 2: Lamp2 Adj.
Lamp1 Status
0: Lamp1 not selected (Select when value is set to 10.)
11: Lamp 1 selected
99: After lamp changed
Lamp2 Status
0: Lamp1 not selected (Select when value is set to 10.)
11: Lamp 1 selected
99: After lamp changed
Sets Lamp CHange Time (unit: hour)
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
(Value will be set after calibration)
Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1
Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2
Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3
Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4
Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5
Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6
Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7
Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8
(Not Memorized)
Flow Sensor Calibration Duty No.1 [%]
Flow Sensor Calibration Duty No.2 [%]
Flow Sensor Calibration Duty No.3 [%]
Flow Sensor Calibration Duty No.4 [%]
Flow Sensor Calibration Duty No.5 [%]
Flow Sensor Calibration Duty No.6 [%]
Flow Sensor Calibration Duty No.7 [%]
Flow Sensor Calibration Duty No.8 [%]
(Not Memorized)
Flow Sensor Calibration Range Diff No.1 [ADC]
Flow Sensor Calibration Range Diff No.2 [ADC]
Flow Sensor Calibration Range Diff No.3 [ADC]
Flow Sensor Calibration Range Diff No.4 [ADC]
Flow Sensor Calibration Range Diff No.5 [ADC]
Flow Sensor Calibration Range Diff No.6 [ADC]
Flow Sensor Calibration Range Diff No.7 [ADC]
Flow Sensor Calibration Range Diff No.8 [ADC]
(Not Memorized )
Flow Sensor Clogged Threshold No.1[ADC]
Flow Sensor Clogged Threshold No.2[ADC]
Flow Sensor Clogged Threshold No.3[ADC]
Flow Sensor Clogged Threshold No.4[ADC]
Flow Sensor Clogged Threshold No.5[ADC]
Range
0 ~ 10
0 - 1
0 - 32767
0 - 32767
0 - 15
0 - 63
0 - 63
1 - 255
0 - 2
-
-
0 - 255
0 - 1
-
0 - 1
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 100
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
0 - 1023
-64-
Initial
Note
0
Initial: 1 / Shipping: 0
7000
15000
0
0
0
50
* Mirror adjustment
0
-
-
10
* Wind sensor
0
calibration.
255
Initial: 0 / Shipping: 1
242
275
309
335
359
378
428
447
31
36
42
48
54
60
80
100
250
250
250
250
250
250
250
250
36
57
75
92
108