  • Page 1 THERMO PRODUCTS USER MANUAL MELINDA IDRO ENGLISH/INGLESE...
  • Page 2 ENGLISH...
  • Page 3: Table Of Contents

    ENGLISH ...................................... 4 WarNINGS ....................................4 SafEty ......................................4 routINE MaINtENaNcE ................................4 HyDrauLIc SyStEM .................................. 5 InstallatIon and safety devIces....................................5 aNtI-coNDENSatIoN DEVIcE (MaNDatory) ........................5 INStaNt DoMEStIc Hot WatEr proDuctIoN kIt ......................6 stove posItIonIng ..........................................6 rEarMING ....................................6 tHErMo-proDuctS fEaturES ..............................
  • Page 4: English

    We thank you for having chosen our company; our product is a great heating solution developed from the most advanced technology with top quality machining and modern design, aimed at making you enjoy the fantastic sensation that the heat of a flame gives, in complete safety. Warnings This instructions manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred to another owner or user, or if transferred to another place.
  • Page 5: Hydraulic System

    HYDRAULIC SYSTEM Certain concepts referring to the Italian Standard UNI 10412-2 (2009) are described in this chapter. As previously described, when installing, all national, regional, provincial and council Standards in force provided by the country in which the appliance has been installed must be complied with. During installation of the generator it is MANDATORY to adjust the system with a manometer in order to display the water pressure.
  • Page 6: Instant Domestic Hot Water Production Kit

    Instant domestIc hot water productIon kIt warnings: if the instant hot water production kit is to be used, contact the company technical after-sales service. stove posItIonIng For correct product functioning, it is recommended to position it in a way that it is perfectly level, with the aid of a spirit level. rearmIng The figures below show the positions for rearming the tank (85°C) and H2O (100°C).
  • Page 7: Installation

    InstallatIon general The flue gas exhaust and hydraulic connections must be carried out by qualified personnel who must issue installation conformity documentation compliant with national standards. the installer must provide the owner or person acting for him, according to the legislation in force, with the declaration of conformity, supplied with: 1) the use and maintenance manual of the appliance and of the system components (such as for example, the smoke ducts, chimney, etc.);...
  • Page 8 In the presence of type B gas appliances with intermittent operation not intended for heating, they must have their own aeration and/or ventilation opening. The air inlets must meet the following requirements: Š they must be protected with grids, metal mesh, etc., but without reducing the net useful section; Š...
  • Page 9: Pellets And Feeding

    Pellets and feeding Pellets are made by applying high pressure to sawdust, or wood waste products (not containing paint) from sawmills, carpentry and other activities related to processing and working with wood. Given that it does not use any glue to hold it together this type of fuel is completely environmentally friendly. In fact the compactness of the pellets over time is guaranteed by a natural substance found in the wood itself: wood coal.
  • Page 10: Control Panel

    Control panel BUTTON Display OF variOUs TO aCCess ON/OFF TexT messages THe meNU aDJUsTmeNT seTTiNg OperaTiNg pOWer TemperaTUre Display iCons key indicates the receipt of the radio signal indicates the stove modulation On = during radio communication On = the stove is working at the set power Off = no radio communication Flashing = the power at which the stove is working is different to Flashing = serial port excluded...
  • Page 11: General Menu

    General menu go back - exit parameter scrolling: next (2) ; previous (3) modify settings data: increase (4); decrease (5) Confirm - access menu seT pOWer pOWer seT TemperaTUre rOOm air Temp seT seT H2O User meNU *eNaBle v1 * air v1 seT CHrONO eNaBle CHrONO reseT...
  • Page 12: The Remote Control

    tHe remote Control all that can normally be implemented through the lCD can be adjusted using the remote control. The table below provides a detailed description of the various functions: on / off pressing the key for three seconds, the stove will switch on or off power inCrease pressing the key will increase the operating power power DeCrease...
  • Page 13: Commissioning Settings

    CommissioninG settinGs Once the power cable at the back of the stove has been connected, move the switch, also located on the back, to (i). The switch at the back of the stove powers the stove board. The stove remains off and a first screen appears on the panel reading OFF. mains frequenCy 50/ 60Hz in the event the stove is installed in a country with 60Hz frequency, the stove will display "frequenza rete errata"...
  • Page 14: Operation And Logic

    operation anD loGiC iGnition Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. 15 minutes are available for the ignition phase. after ignition and having reached the control temperature, the stove interrupts the ignition phase and passes to sTarTiNg. startinG During the start-up stage, the stove stabilises combustion, increasing it gradually, to then start ventilation and switch to the WOrk mode.
  • Page 15: Additional Thermostat

    aDDitional tHermostat n.B. : installation must be performed by an authorised technician. There is a possibility to thermostat a room adjacent to the room where the stove is positioned: just connect a thermostat following the procedure described in the next step (it is recommended to position the optional mechanical thermostat at a height of 1.50 m from the floor) . stove functioning with the external thermostat connected in the sTBy clamp can be different on the basis of the activation or disabling of the sTBy function.
  • Page 16: Set Power

    set power The following menu allows you to set the generator power minimum power 1, maximum power 5. CONTrOls prOCeDUre press key 6. � Confirm using key 6 - set power. � � Use keys 4 or 5 to set the power. press key 1 several times to confirm and exit the menu.
  • Page 17: Reset

    reset allows the user to reset all values modifiable by the user to the default values. CONTrOls prOCeDUre press key 6. � proceed by pressing key 2 until user menu is displayed. � Confirm using key 6. � press key 2 until reset is displayed. �...
  • Page 18: Status

    CONTrOls prOCeDUre � press key 6. � proceed by pressing key 2 until set CHrono is displayed. � Confirm using key 6. � Use keys 4-5 to enable/disable - set/edit the time. � press key 2 to go forwards 3 to go back. �...
  • Page 19: Stand - By

    key loCk The menu allows the user to lock the display keys (like with mobile phones). CONTrOls prOCeDUre � press key 6. � proceed by pressing key 2 until settinGs is DisplayeD. � Confirm using key 6. � press key 2 until Display is shown. � Confirm using key 6.
  • Page 20: Cleaning And Maintenance

    Cleaning and maintenanCe always follow the instruCtions in maximum safety Conditions! Make sure the power cable's plug has been pulled out, as the generator might have been programmed to turn on. Make sure all the parts of the generator are cold. The ashes are completely cold.
  • Page 21 daily scrapers : Cleaning the heat exchangers allows the user to guarantee constant heat output over time. This type of maintenance must be performed at least once a day. To do this, just use the relevant scrapers positioned in the upper part of the stove, making upward movements and vice versa several times.
  • Page 22: Routine Maintenance Carried Out By Authorised Technicians

    - melinda idro Remove the ash accumulated at the top of the hearth wall (see figure below) routine maintenanCe Carried out By authorised teChniCians routine maintenance must be performed at least once a year. As the generator uses pellets as solid fuel, it needs an annual routine maintenance interval that needs to be performed by an authorised technician by only using original spare parts.
  • Page 23 routine maintenanCe The images are for illustration purposes.  Fumes motor (disassembly and cleaning and fumes pipe and "T"), new silicone in required points  Inspections of gaskets, ash drawer and door (replace them and apply silicone where required)  Combustion chamber &...
  • Page 24: Displays

    Displays Display Reason Generator off sTaRT The start-up phase is in progress pelleT feeDinG Continuous pellet feeding is in progress during the ignition phase iGniTion The ignition phase is in progress sTaRT-up The start-up phase is in progress WoRk The normal work phase is in progress MoDulaTion The generator is working at minimum BuRn poT cleaninG...
  • Page 25 fuMes pRoBe Fumes probe failure. Contact after-sales centre Check pellet feed (see “Pellet feed adjustment”). If the problem cannot be HoT fuMes High flue gas temperature solved, contact an authorised technician. The door is not closed correctly. Check hermetic door closure. The ash drawer is not closed correctly.
  • Page 26 ENGLISH...
  • Page 27 ENGLISH...
  • Page 28   +39.0445.865911 -  +39.0445.865912 -  info@extraflame.it - www.lanordica-extraflame.com The Manufacturer reserves the right to vary the features and data shown in this booklet at any time and without prior notice, in order to improve its products. This manual cannot be considered as a contract for third parties.