Cushman MINUTE MISER 628808 Owner's Manual page 61

Table of Contents

Advertisement

Read all of this manual to become thoroughly familiar with this vehicle. Pay particular attention to all Notices, Cautions, Warnings, and Dangers.
Troubleshooting Instructions
If a fault occurs, count the number of red flashes between pauses and refer to the table below:
Red Flashes
Specifications
DC Output – see Operating Instructions
QuiQ Model:
Voltage-nom (V)
Voltage-max (V)
Current-max (A)
Battery Type
Reverse Polarity
Short Circuit
AC Input
All models
Voltage-max (Vrms)
Frequency (Hz)
Current - max (Arms)
AC Power Factor
Mechanical
All models
Dimensions
Weight
Environmental
Operating
Temperature
Storage Temperature
AC input connector
DC output
Product warranty is dependent on model - please contact dealer of original equipment for warranty service.
Note: This is a Class A product. In a domestic environment this product may cause radio interference, and the user may be required to take adequate measures.
2012 © Delta-Q Technologies Corp. All rights reserved. PN: 710-0141 Rev 1
Cause
Charge Enable Fault or
Battery Temperature Fault
Battery Voltage Too Low or High
Charge Timeout caused by battery
pack not reaching required voltage.
Charger output was reduced due to
high temperatures.
Check Battery: battery could not be
trickle charged up to minimum voltage
Over-Temperature: Charger shut
down due to high internal
temperature.
Charger Internal Fault
912-2400
912-3600-07
912-4800-14
628089
628102
624206
24
36
34
51
25
21
Lead acid (Wet / AGM / GEL)
Electronic protection – auto-reset
Electronic current limit
85 – 265
45 - 65
9.5A @ 120VAC
5A @ 230VAC
>0.99 at 120VAC
>0.98 at 230VAC
28.0 x 24.5 x 11.0 cm (11 x 9.7 x
4.3”)
<5 kg (11 lbs)
Enclosure: IP66
-30°C to +50°C (-22°F to 122°F),
derated above 30°C, below 0°C
-40°C to +70°C (-40°F to 158°F)
IEC320/C14
(require •1.8m localized cord)
OEM specific w/ 12AWG wire
Solution
Check connector contacts and retry.
Check that battery temperature is between
-10°C and +50°C.
Check battery size and condition of
batteries.
Check for loose connections or corrosion.
Operate charger at a lower ambient
temperature or increase cooling air flow.
Check for shorted or damaged cells.
Ensure sufficient cooling air flow and reset
charger (interrupt AC power for 15
seconds).
Reset charger (interrupt AC power for 15
seconds). Return to qualified service depot
if fault persists.
Operation
All models
Battery Temperature
48
Compensation
67
Maintenance Mode
18
Regulatory
Safety
EN 60335-2-29
st
UL2202 (1
Ed.)
UL1564 3rd Ed.
CSA- 107.2
Emissions
FCC Part 15/ICES
003
EN 55011
EN 61000-3-2
EN 61000-3-3
Immunity
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
APPENDIX A
w/Default Algo 1
Automatic
Auto-restart if V < 2.08V/cell
or 30 days elapse
Safety of Appliances/ Battery Chargers
EV Charging System Equipment
Industrial Battery Charger
Battery Chargers- Industrial
Unintentional Radiators Class A
Radio disturbance characteristics
(Class A)
Limits for harmonic current emissions
Limits of voltage fluctuations and
flicker
Electrostatic discharge immunity
Radiated, radio-frequency,
EMF immunity
Electrical fast transient/burst immunity
Surge immunity
Conducted Immunity
Voltage variations immunity
A - 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents