Well Water Purifi er
Owner's Manual and Usage Guide
MODEL ZO-400 / ZO-400-25
P/N: 4-1377-01_Rev.B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the aquaclipse ZO-400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Del ozone aquaclipse ZO-400

  • Page 1 Well Water Purifi er Owner’s Manual and Usage Guide MODEL ZO-400 / ZO-400-25 P/N: 4-1377-01_Rev.B...
  • Page 2: Table Of Contents

    Aquaclipse™ Installation & Operation Manual Table of Contents IMPORTANT SAFETY INSTRUCTIONS SECTION 1. General Information 1A Description Read and Follow All Instructions 1B Specifications • Read this manual completely before attempting installation. SECTION 2. Installation • All permanent electrical connections should be made by a quali ed electri- 2A Recommended Installation cian.
  • Page 3: Section 1 General Information

    SECTION 2 Installation Description Recommended Installation for wells The DEL Ozone Aquaclipse Corona Discharge (CD) ozonator is designed and holding tanks to pump ozone gas into liquids for purification on new, existing or multiple Refer to Figure 2 (Next Page) well water tanks.
  • Page 4: Electrical

    AQUACLIPSE Timer The DEL Ozone Aquaclipse has a digital timer on the front panel for timed operation control. When the timer is set to power the system, the 4 indicator lights on the front panel below the timer will light green when the ozone cells are functioning properly.
  • Page 5: Section 5 Maintenance And Service

    Aquaclipse™ Installation & Operation Manual When used in con junction with a particulate filter, ozone will also remove excess minerals including iron, manganese, and lead, as well as radon and sulfur gases. It is recommended you check your filters about 1 month after installation Lift the face plate off and out of the way being careful not to of ozone equipment to gage rate of clogging.
  • Page 6: Cleansing The Dispersion Stone

    Aquaclipse™ Installation & Operation Manual Cleaning the dispersion stone pH not balanced Adjust pH to 7.2 to 7.8 Periodically, the dispersion stone may clog up with mineral deposits Total alkalinity incorrect Adjust total alkalinity to reducing the amount of ozone flow through the stone. The stone will 80 –...
  • Page 7 Aquaclipse™ Installation & Operation Manual #3 Setting each cycle to “switch off” NOTE: to save time you can set up each on/off cycle; Slide RUN switch to “P” press “p” button, note switch cycle A) to be unique for each individual day, or number changes to 2 and bulb blinks, indicating B) for Monday to Friday (days 1 to 5), or C) for weekends only (days 6 &...
  • Page 8: Warranty

    DEL Ozone warrants that it or its authorized dealers will repair or replace, at its option, any part of such products proven to be defective in materials or workmanship within ONE (1) year from the date of retail purchase of such products.
  • Page 9 EPA Estab. No. 071472-CA-001 San Luis Obispo, California, 93401 Phone 805.541.1601 800.676.1335 805.541.8459 www.delozone.com...