● Primary fixing locations (x4).
4. Mark the location on the wall with a pencil.
Use the backplate to mark the locations
for the four fixing points.
5. Drill holes
6. Fix the optional back panel if required.
3.1
Rear cable entry.
6mm
● Primary fixing locations (x4).
Do not use countersunk screws.
Fixing the backplate to the wall.
Fit the backplate securely to the wall using the
appropriate fixings for the wall type and weight
of the unit. Do not use counter-sunk screws.
Do not secure tightly until after the power cable
has been secured.
Installing the power cable.
1. Cut the entry hole in the rubber cable
grommet to the correct size: leave a hole
smaller than the diameter of the power cable
to ensure the cable fits tightly.
5
2. Pull the cable through the grommet. Ensure
the cable is long enough to route correctly
through the backplate to the terminal block.
The cable must sit in the dedicated channel.
3. Fit the grommet into the backplate.
Ensure it is secure.
4. Secure the screws in the backplate.
5. Proceed with step 4, 'Connecting to
terminal block'.