    BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 1 Dienstag, 25. August 2009 3:33 15 Operating manual Differential temperature control Version 0931-10 Art. 0450021000...
  • Page 2: Table Of Contents

    Declaration of conformity ....................13 Technical Data ........................ 14 Liability ..........................14 Disposal ........................... 14 © Elektronikbau- und Vertriebs GmbH Heisterner Weg 8 - 12 D-57299 Burbach This document may not be reproduced nor disclosed to third parties, particularly competitors, in original or copy form without our prior explicit consent.
  • Page 3: Scope Of Delivery

    BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 1 Dienstag, 25. August 2009 3:33 15 Scope of delivery 1. 1x Central unit CETA 100 2. 1x Tank immersion sensor KVT 20/2/6 3. 1x Collector sensor PT1000/6 4. 8x Screw, plate 2.9x19 mm 5. 3x Screw assembly 4x35 mm 6.
  • Page 4: General Key Functions

    BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 2 Dienstag, 25. August 2009 3:33 15 General key functions General key functions Prog •Change selected submenus •Change (parameter) setting •Save value + (Plus) or - (Minus) •Change parameter •Change menu item •Exit setting •Keep old value •Select next higher menu level Esc-Long •Return to basic display 2.
  • Page 5: Menu Level

    BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 3 Dienstag, 25. August 2009 3:33 15 Menu level 4. Menu level General menu structure Ceta series Basic display Prog Select parameters Menu 01 Prog 02:01 02:02 02:nn Menu 02 Parameter 01 Parameter 02 Last parameter Prog Prog Value 1 Calibration Set parameter value...
  • Page 6 BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 4 Dienstag, 25. August 2009 3:33 15 Menu level Overview of menu level Basic display Prog 08:03 08:01 08:02 Pump Info Heat capacity Heat balance On/Off Prog 03:01 03:02 03:03 System Code entry Auto set function Bus address Prog 08:01 08:02...
  • Page 7 BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 5 Dienstag, 25. August 2009 3:33 15 Menu level 08:04 08:05 08:07 08:08 08:06 Temperature Temp. heat Pump operating Pump starts Temp. return flow heat supplier storage tank hours 03:06 03:07 03:09 03:10 Automatic Anti-blocking Code heating Reset p arameter specialist exit time prot.pump...
  • Page 8: Parameter Description

    Setting range: 21…25 Factory setting: 21 Function: If more than one CETA 100 or 101 has to be connected via data bus within a system, each unit must be set to a unique address. 03:06 Automatic exit time Setting range: 0.5 …...
  • Page 9 BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 7 Dienstag, 25. August 2009 3:33 15 Parameter description Display Designation Description 03:07 Anti-blocking Setting range: 0 = OFF protection 1 = ON Factory setting: OFF Function: Pump is switched on 20 s daily during extended shutdown (> 24h) as protection against blocking when function is activated. 03:09 Code heating Setting range:...
  • Page 10 BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 8 Dienstag, 25. August 2009 3:33 15 Parameter description Display Designation Description 08:05 Minimum Setting range: OFF (----) temperature heat 5…80 °C supplier Factory setting: OFF Function: Irrespective of switching differentials, pump turns on only after the sensor of heat supplier F3 has exceeded the set value. 08:06 Maximum Setting range:...
  • Page 11: Sensor Calibration

    BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 9 Dienstag, 25. August 2009 3:33 15 Parameter description Display Designation Description 08:12 Volume flow HT- Setting range: 0.0 … 30 l/min medium Factory value: 0.0 l/min Function: Here the volume flow is set in litre/minute when calculating flow rate, according to respective pump capacity.
  • Page 12: Mounting

    BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 10 Dienstag, 25. August 2009 3:33 15 Mounting 6. Mounting Hazard! Mounting must be performed by an authorised professional electrician! Ensure that unit is de-energised before opening it! Drilling pattern for wall fastening 1. Remove terminal area cover from casing.
  • Page 13: Connection Diagram

    BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 11 Dienstag, 25. August 2009 3:33 15 Connection diagram Connection diagram Hazard! Connection must be performed by an authorised professional electrician! Ensure that unit is de-energised before opening it! 230V connections Low voltage connections 8. Fault clearance To allow an accurate diagnosis in case of malfunction, the unit is equipped with a fault display system.
  • Page 14: Sensor Resistance Values

    BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 12 Dienstag, 25. August 2009 3:33 15 Sensor resistance values Fault overview: Fault code Cause Repair 0--- Tank sensor interruption Check cable and plug connection; repair if necessary 1--- Short circuit on tank sensor Replace tank sensor Fault Cause Repair Display text not visible...
  • Page 15: Declaration Of Conformity

    BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 13 Dienstag, 25. August 2009 3:33 15 Declaration of conformity 10. Declaration of conformity Elektronikbau- und Vertriebs- GmbH Heisternerweg 8-12, 57299 Burbach EC Declaration of Conformity Product identification: Heating controller Type designation: CETA 100 Manufacturer: EbV Elektronikbau- und Vertriebs-GmbH...
  • Page 16: Technical Data

    BA_CETA100_EbV_EN_0450021000_0931-10.book Seite 14 Dienstag, 25. August 2009 3:33 15 Technical Data 11. Technical Data Mains voltage: 230V +6%/ -10% Rated frequency: 50...60Hz Power input: max. 2.1VA Fuse: 6.3A Output relay contact load: 2 (2) A Ambient temperature: -10...+50 °C Storage temperature: -25...+80 °C Degree of protection: IP 30...