3
Input Temperature Sensor Type
Platinum resistance (Pt100) type3
Platinum resistance (Pt100) type2
Platinum resistance (Pt100) type1
Platinum resistance (JPt100) type2
Platinum resistance (JPt100) type1
Thermocouple (TC) B type
Thermocouple (TC) S type
Thermocouple (TC) R type
Thermocouple (TC) N type
Thermocouple (TC) E type
Thermocouple (TC) T type2
Thermocouple (TC) T type1
Thermocouple (TC) J type2
Thermocouple (TC) J type1
Thermocouple (TC) K type2
Thermocouple (TC) K type1
Thermocouple (TC) L type
Thermocouple (TC) U type
Thermocouple (TC) Txk type
4
There are three modes of operation: operation, regulation and initial setting. When power is applied, the controller will default to the
operation mode. Press the
switch to the initial setting mode. Pressing the
to the operation mode. PV/SV : Sets the temperature set point and displays the temperature process value. Use the
set the temperature set point.
Setting method: While in any function mode, press the
settings. Press
key to save the changes. Menu items are listed below.
Regulation Mode
Auto-tuning
(Set in PID control and RUN mode)
Press
Set proportional band (Kp)
(in PID control)
Press
Set integral time (Ki)
(in PID control)
Press
Set derivative time (Kt)
(in PID control)
Press
or
P/PD control offset (when
PID control is ON and Ki=0 set the value of
PdoF. If Ki≠0, AT (auto-tuning, will
automatically set the value of ioF.
Press
or
Heating/Cooling hysteresis.
(in ON/OFF control)
Press

Temperature Sensor Type and Temperature Range

Register Value
key to switch to regulation mode. If the
key while in the regulation mode or initial setting mode, forces the controller to return
Use
set temperature set point
Press
Control setting RUN or STOP
Press
Upper-limit alarm 1
(This parameter is available only when
ALA1 function enables)
Press
Lower-limit alarm 1
(This parameter is available only when
ALA1 function enables)
Press
Upper-limit alarm 2
(This parameter is available only when
ALA2 function enables)
Press
Lower-limit alarm 2
(This parameter is available only when
ALA2 function enables)
Press
LED Display
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
16
17
18
Operation
key is pressed for more than 3 seconds, the controller will
key to select the desired function and use the
Operation Mode
key to
Temperature Range
0.0 to 100.0
-20.0 to 500.0
-200 to 600
0.0 to 100.0
-20.0 to 400.0
100 to 1800
0 to 1700
0 to 1700
-200 to 1300
0 to 600
-20.0 to 400.0
-200 to 400
-20.0 to 400.0
-100 to 850
-20.0 to 500.0
-200 to 1300
-200 to 850
-200 to 500
-200 to 800
and
keys to change
Initial Setting Mode
Set input type
Press
Set temperature unit
do not display when analog input
Press
Set upper-limit of
temperature range
Press
Set lower-limit of
temperature range
Press
Sets Control Method: on/off, PID, or
manual.
Select heating or cooling control.
Press
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
o
C
and
keys to

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C Series and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF