Addi onal clearances
Check to determine hether local codes supersede
these clearances.
Avoid termina on loca ons near a dryer vent.
•
Avoid termina on loca ons near commercial
•
cooking exhaust.
Avoid termina on loca ons near any air inlets.
•
ou must install a vent termina on at least 12
•
inches above the ground or an cipated sno
level.
UC80i, UC90i, UC98i
The vent for this appliance shall not terminate
ver public alk ays; or
•
ear so t vents or cra l space vents or other
•
area here condensate or vapor could create a
nuisance or ha ard or cause property damage; or
Where condensate or vapor could cause damage
•
or could be detrimental to the opera on of
regulators, relief valves, or other equipment.
m
d
termina on under a so t (ven lated or unven lated
or eave vent; or to a deck or porch)
Do not install vent termina on under a so t vent
•
such that exhaust can enter the so t vent
Install vent termina on such that exhaust and rising moisture
•
ill not collect under eaves. Discolora on to the exterior of
the building could occur if installed too close.
Do not install the vent termina on too close under the so t
•
here it could present recircula on of exhaust gases back
into the combus on air intake part of the termina on.
(0.30 m ) to
an inside
corner
36"
12"
V
12"
INSIDE
CORNER
for loca ng vent
V
(0.30 m) bet een
terminals at same
level
KBD Series Manual
(50 mm) bet een
terminals at same level
12"
(0.30 m) to an
inside corner
(1.52 m)
bet een
terminals at
di erent levels
V
(1.52 m)
ver cally
bet een
60"
terminals
V
U80e, U90e, U98e
(0.91 m) to ven lated
or unven lated so t
or eve vent; or to a
36"
deck or porch
2"
(1.52 m) ver cally
bet een terminals
60"
60"
V
(0.61 m) to all or parapet
24"
V
12"
(0.30 m) bet een
V
V
terminals at same
level
V
9