Locating Your Grill - Lynx L27F Installation Use And Care Manual

Table of Contents

Advertisement

Locating Your Grill
When selecting
a suitable
loca-
tion, take into account concerns
such as exposure
to wind
and
traffic paths. Try to keep all gas
supply lines as short as possible.
Never locate the grill in a build-
ing, garage, shed or other such
enclosed
area.
A
carpenter's
"spirit level" should
be used to
assure that the unit is level both
front-to-back
and
side-to-side.
If it is not level, burner combus-
tion may be erratic or the unit
may not function
efficiently.
If
the floor is uneven or has a de-
cided slope, re-leveling
may be
required after each moving of a
freestanding
unit.
BUILT-IN INSTALLATIONS:
The LYNX Built-In Grill is designed
for easy installation
into mason-
ry enclosures. For non-combus-
tible applications,
the grill drops
into the opening
shown in the
cutout detail drawing and hangs
from its counter-top
trim. A deck
is not required to support it from
the bottom.
When using the in-
sulated jacket
in a combustible
enclosure,
the jacket
must
be
supported
from the bottom
by a
ledge on each side or a full deck
beneath
the jacket. Review the
detailed
drawing
and pay spe-
cial attention
to the provisions
shown for gas line hook-up. It is
recommended
that
the enclo-
sure have ventilation
holes to
prevent gas build-up
in the event
of a leak. The deck ledges and
counter should be flat and level.
If your grill is equipped with a ro-
tisserie, electrical
service should
be provided
(on the Left Side of
most models).
REAR HOOD CLEARANCE:
Clearance is required behind the
grill to allow the front hood to
open (see figure 4-1). 27" and 36"
models require a minimum
of 2"
clearance, while 30", 42" and 54"
models
require
a minimum
of
4" clearance. The grill exhausts
combustion
products
and cook-
ing greases to the back. Never lo-
cate the grill where this exhaust
will be difficult to clean.
2" min. for 27"and 36" grills
4" min. for 30", 42"and 54" grills
Figure
4-1 - Required clearance
to allow opening of front hood.
CLEARANCE TO COMBUSTIBLE
CONSTRUCTION:
Minimum
clearance from sides
and back of unit
to
adjacent
combustible
construction
below
top of unit are 12" from sides and
12" from back.
D_gagement
minimal
entre les
parois
lat_rales
et I'arri@re de
I'appariel et la construction
com-
bustible au-dessous du panneau
sup_rieur de I'appareil
(30 cm
partir des parois lat_rales et 30 cm
partir de I'arri_re).
Minimum
horizontal
clearance
from sides and back of unit to
adjacent
vertical
combustible
construction
extending
above
top of unit is 12" from sides and
12" from back.
D_gagement
horizontal
minimal
entre les parois lat_rales et I'arri_re
de I'appariel
et la construction
verticale
combustible
au-dessus
de I'appareil (30 cm _ partir des
parois lat_rales et 30 cm _ partir
de I'arri_re).
Do not use this appliance
under
overhead combustible
surfaces.
Ne pas utiliser cet appareil sous
une surface combustible.
A minimum
of 6" of clearance is
needed on each side of the grill
for the motor and skewer.
If the grill is to be placed into a
combustible
enclosure,
an ap-
proved insulated jacket is neces-
sary and is available
from your
LYNX dealer. Use only a LYNX in-
sulated jacket as it has been de-
signed and tested specifically for
your Grill. Refer to next page for
cutout dimensions.
WARNING
Installing
this
product
into
a combustible
en-
closure
without
an insu-
lated
jacket
could
result
in fire,
property
damage
and personal injury.