Download Print this page

Blood Pressure Monitor - Medisana BU 530 Instruction Manual

Hide thumbs Also See for BU 530:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 2
DE/GB

Blood Pressure Monitor

BU 530
Instruction Manual
Please read carefully!
GB Unit and LC-Display
8
7
4 x LR03,
1,5 V, AAA
6
5
1
p
o
(b)
2-3 cm
(a)
2
i
u
z
t
r
(c)
3
Proper use
The device is intended for measuring the blood
pressure from the upper arm of an adult.
Contraindications
The device is not suitable for measuring the
blood pressure of children. Ask your doctor
before using it on older children.
Persons who suffer from arrhythmia, diabetes,
cardiovascular problems or who have had a stroke
should consult their doctor before using the device.
Explanation of symbols
Common factors of wrong measurements
IMPORTANT
Follow the instructions for use!
Please keep quiet for 5-10 minutes and avoid eating,
Non-observance of these instructions
drinking alcohol, smoking, exercising and bathing
can result in serious injury or damage
before taking a measurement. All these factors will
to the device.
influence the measurement result.
Remove any garment that fits closely to your
WARNING
upper arm.
These warning notes must be observed
Always measure on the same arm (normally left).
to prevent any injury to the user.
Measurements should be taken regularly at the
same time of each day, as the blood pressure varies
CAUTION
even during the day.
These notes must be observed to prevent
Any effort to support the arm during measurement
any damage to the device.
may increase the measured blood pressure.
Make sure, you are in a comfortable, relaxed posi-
tion and do not move or constrict your muscles
NOTE
during measurement. Use a cushion to support your
These notes give you useful additional
arm if necessary.
information on the installation or
If the arm artery lies lower or higher than the heart,
operation.
a false reading will be obtained.
A loose or open cuff causes false readings.
With repeated measurements , blood accumulates
Device classification: type B applied part
in the arm which can lead to false reading.
Consecutive blood pressure measurements should
be repeated after 1 minute pause or after the
LOT number
arm has been held up in order to allow the
accumulated blood to flow away.
Manufacturer
Date of manufacture
GB
Safety Instructions
Read the instruction manual carefully before
using this device, especially the safety
instructions, and keep the instruction manual
for future use. Should you give this device to
another person, it is vital that you also pass on
these instructions for use.
The unit is intended only for use in the home. Consult your doctor prior to
using the blood pressure monitor if you are concerned about health matters.
Only use the unit for its intended purpose in accordance with the instructions
for use. Warranty claims become void if the unit is misused.
Please consult your doctor prior to using the unit if you suffer from illnesses
such as arterial occlusive disease.
The unit may not be used to check the heart rate of a pacemaker.
Pregnant women should take the necessary precautions and pay attention to
their individual circumstances. Please consult your doctor if necessary.
Consult your physician to get more information about your blood pressure. A
self-diagnosis and self-treatment based on the measured values may be
dangerous. Always follow the instructions given by your physician!
If you experience discomfort during a measurement, such as pain in the upper
arm or other complaints, press the START/STOP-button
4
immediately from the cuff. Loosen the cuff and remove it from your arm.
The device only works correct with the fitting cuff.
The unit is not suitable for children.
Do not allow children to use the unit. Medical products are not toys!
Please ensure that the unit is kept away from the reach of children.
1
Do not put the air tube around your neck - danger of suffocation!
The swallowing of small parts like packaging bag, battery, battery cover and
so on may cause suffocation.
The user needs to check that the equipment functions properly and that it is in
2
proper working condition before being used.
Only the cuff provided can be used, and cannot be changed to any other
3
branded cuff. It can only be replaced with a cuff of exactly the same type.
The device may not be operated in rooms with high levels of radiation or in
the vicinity of high-radiation devices, such as radio transmitters, mobile tele-
4
phones or microwaves, as this could cause functional defects or incorrect
measurements.
Do not use the equipment where flammable gas (such as anaesthetic gas,
oxygen or hydrogen) or flammable liquids (such as alcohol) are present.
No modification of this unit/device is allowed.
Please do not attempt to repair the unit yourself in the event of malfunctions,
since this will void all warranty claims. Only have repairs carried out by
authorised service centres.
9
Protect the unit against moisture. If liquid does manage to penetrate into the
unit, remove the batteries immediately and do not continue to use the unit. In
this case contact your specialist dealer or notify us directly.
0
Please do not use a dilution agent, alcohol or petrol to clean the unit.
Please do not hit the device heavily or let if fall down from a high place.
Do not use mobile phones in the range of the device. This may lead to mal-
functions.
If the unit is not going to be used for a long period, please remove the
q
batteries.
w
SAFETY NOTES FOR BATTERIES
e
Do not disassemble batteries!
Replace all batteries if the unit display shows the low battery symbol.
Never leave any low battery in the battery compartment since it may leak and
cause damage to the unit.
Increased risk of leakage! Avoid contact with skin, eyes and mucous mem-
branes! If battery acid comes in contact with any of these parts, rinse the
affected area with copious amounts of fresh water and seek medical attention
immediately!
If a battery has been swallowed, seek medical attention immediately!
Replace all of the batteries simultaneously!
Only replace with batteries of the same type, never use different types of
batteries together or used batteries with new ones!
Insert the batteries correctly, observing the polarity!
Remove the batteries from the device if it is not going to be used for an exten-
ded period of 3 months or more!
Keep batteries out of children's reach!
Do not attempt to recharge batteries! There is a danger of explosion!
Do not short circuit! There is a danger of explosion!
Do not throw into a fire! There is a danger of explosion!
Do not throw used batteries into the household refuse; put them in a
hazardous waste container or take them to a battery collection point, at the
shop where they were purchased!
Unit and LCD display
1
Socket for mains adaptor
2
Blood Pressure Monitor
3
4
5
(Memory Recall)
START/STOP button
SET button
Compartment (on underside)
7
Push-in Connector for air tube
8
LCD screen (display)
9
Display of Date/Time
0
Display of Systolic
q
w
Pressure
Display of Diastolic Pressure
Pulse symbol
r
t
Pulse Rate
Change Battery symbol
Arrhythmia display (arrhythmia
cordis)
z
Memory Location number
u
Memory-Symbol
o
symbol
Blood Pressure Indicator (green - yellow - orange - red)
p
User memory 1 / 2 / Guest
Scope of supply
Please check first of all that the unit is complete.
The following parts are included as standard:
• 1 MEDISANA blood pressure monitor BU 530
• 1 cuff with air tube
• 4 batteries (type AAA, LR03) 1.5 V
• 1 storage pouch
• 1 instruction manual
Please contact your supplier if you notice any transport damage on unpacking
the unit.
What is blood pressure?
Blood pressure is the pressure created in the blood vessels by each heart beat.
When the heart contracts (= systole) and pumps blood into the arteries, it brings
about a rise in pressure. The highest value is known as the systolic pressure
and is the first value to be measured. When the cardiac muscle relaxes to take
in fresh blood, the pressure in the arteries also falls. Once the arteries are re-
laxed, a second reading is taken – the diastolic pressure.
How is blood pressure measured?
The MEDISANA BU 530 is a blood pressure unit which is used to measure
blood pressure at the upper arm. The measurement is carried out by a micro-
processor, which, via a pressure sensor, measures the vibrations resulting from
the inflation and deflation of the cuff over the artery.
Blood pressure classification WHO
These values have been specified by the World Health Organisation (WHO)
without making any allowance for age.
Low blood pressure
systolic <100
diastolic <60
o
Normal blood pressure
(green display area
)
systolic 100 - 139 diastolic 60 - 89
Forms of high blood pressure / hypertension
o
Mild hypertension
(yellow display area
)
systolic 140 – 159 diastolic 90 – 99
Moderate hypertension
(orange display area
o
)
systolic 160 – 179 diastolic 100 – 109
o
Severe hypertension
(red display area
)
systolic ≥ 180
diastolic ≥ 110
WARNING
Blood pressure that is too low represents just as great a health
risk as blood pressure that is too high! Fits of dizziness may
lead to dangerous situations arising (e.g. on stairs or in traffic)!
i
Influencing and evaluating readings
i
Measure your blood pressure several times, then record and compare the
i
results. Do not draw any conclusions from a single reading.
Your blood pressure readings should always be evaluated by a doctor who is
i
also familiar with your personal medical history. When using the unit regularly
and recording the values for your doctor, you should visit the doctor from time
to time to keep him updated.
i
When taking readings, remember that the daily values are influenced by se-
veral factors. Smoking, consumption of alcohol, drugs and physical exertion
to release the air
influence the measured values in various ways.
i
Measure your blood pressure before meals.
i
Before taking readings, allow yourself at least 5-10 minutes rest.
i
If the systolic and diastolic readings seem unusual (too high or too low) on
i
several occasions, despite correct use of the unit, please inform your doctor.
i
This also applies to the rare occasions when an irregular or very weak pulse
i
prevents you from taking readings.
i
i
Starting up
Insert / replace batteries
i
You must insert the batteries provided before you can use your unit. The lid of
the battery compartment
6
is located on the underside of the unit. Open it by
slightly pushing it and moving it upwards. Remove it and insert the 4 AAA LR03
type 1.5V batteries supplied. Ensure correct polarity when inserting the batteries
i
(as marked inside the battery compartment). Close the battery compartment.
Replace the batteries if the change battery symbol
r
appears on the display
i
if nothing appears on the display after the unit has been switched on.
i
Using a Mains Adaptor
Alternatively, you can use the unit with a special mains adaptor (MEDISANA Art.-
i
No. 51125). This connects to the socket
1
provided at the back of the unit. In
this case the batteries remain in the unit. Inserting the connector into the back of
the blood pressure monitor switches the batteries off mechanically.
i
It is necessary, therefore, to plug the mains adaptor into the mains socket first of
i
all and then to connect it to the blood pressure monitor. If the blood pressure
i
monitor is no longer being used, first remove the connector from the blood pres-
sure monitor and then pull the mains adaptor out of the mains socket. Doing this
i
means that the date and time will not have to be reset each time.
Settings
1. User setting:
When unit is switched off, press and hold SET-button
5
.
,
or
i
on the display. By pressing MEM-button
3
you may choose between user
i
or
. Press SET button
5
to confirm the user setting. Afterwards, you can
G
proceed with the year setting mode.
i
Hint: If you have chosen
, measurement results will not be stored.
G
2. Year setting:
i
The year figure starts to flash for setting. Keep pressing the MEM button
5
i
until the actual year figure appears. Press SET button
to confirm the year
i
setting. Afterwards, you can proceed with the month/date setting mode.
3. Month / date setting:
i
i
The month figure starts to flash for setting. Keep pressing the MEM button
3
5
until the actual month figure appears. Press SET button
to confirm the
i
month setting. Afterwards, the day needs to be set in the same way. After-
i
wards, you can proceed with the time setting mode.
i
i
4. Time setting:
i
The hour figure starts to flash for setting. Keep pressing the MEM button
until the actual hour figure appears. Press SET button
5
to confirm the
hour setting and proceed in the same way for minute setting. Conclusively,
CL appears in the display. You may delete stored values at this point -
please check chapter „Memory- clear of measurements". Press SET button
5
to leave the setting mode. If the batteries are changed, the set infor-
mation is lost and needs to be input again.
MEM button
6
Fitting the cuff
Battery
7
1.
Push the end piece of the air tube
into the hole on the left side of the unit
prior to use.
e
2.
Slide the open end of the cuff through the metal bracket so that the Velcro
Display of
fastener is on the outside and it becomes a cylindrical form (Fig.1). Slide the
cuff over your left upper arm.
i
Bluetooth
®
3.
Position the air hose in the middle of your arm in line with your middle finger
(Fig.2) (a). The lower edge of the cuff should be 2 - 3 cm above the crease of
the elbow. (b). Pull the cuff tight and close the Velcro fastener (c).
4.
Measure the pulse on your bare arm.
5.
Only position the cuff on the right arm if it cannot be used on the left arm. Al-
ways carry out measurements on the same arm.
6.
Correct measuring position for sitting (Fig.3).
Taking a blood pressure measurement
After the cuff has been appropriately positioned,the measurement can begin:
1.
Switch the unit on by pressing the START/STOP button
4
.
2.
If the START/STOP button
4
is pressed, all display characters are shown
(display test). This test can be used to check that the display is indicating
properly and in full.
3.
The unit is ready for measurement. The number 0 flashes for 2 seconds and
two short beeps are emitted. The device then automatically inflates the cuff
slowly in order to measure your blood pressure. The rising pressure in the
cuff is shown on the display.
4.
The unit inflates the cuff until sufficient pressure has built up for a measure-
ment. Then the unit slowly releases air from the cuff and carries out the
measurement. When the device detects the signal, the heart symbol
the display starts to flash, you can hear the beep for every heartbeat once
the heartbeat signal is detected.
5.When the measurement is finished, you can hear a long beep and the cuff is
deflated completely. The systolic and diastolic blood pressure and the pulse
o
value appear on the display
8
. The blood pressure indicator
is displayed
next to the relevant coloured bar depending on the WHO blood pressure
classification. If the unit has detected an irregular heartbeat, the arrhythmia
t
display
also appears.
WARNING
Do not take any therapeutic measures on the basis of a self
measurement. Never alter the dose of a medicine prescribed
by a doctor.
6.
The readings are automatically saved in the previously selected memory
(
or
). Up to 120 measured values with date and time can be stored
in each memory.
7.
The measurement readings remain on the display. The unit switches off
automatically after approx. 3 minutes if no buttons are pressed. The unit
may also be switched off using the START/STOP button
4
.
®
®
Transfer via Bluetooth to VitaDock+ app
The MEDISANA Blood Pressure monitor BU 530 offers the possibility to transfer
®
®
your measured values via Bluetooth to the VitaDock+
app. The VitaDock+®
app allow the evaluation, storage and synchronisation of your data between
multiple iOS- and Android-devices to have access to it anytime and anywhere. You
i
may share your results with your friends or your doctor. Therefore you need a free
user account, which you can create on the website www.vitadock.com. For Android
or iOS mobile devices, you may download the respective apps. After each
measurement an automatic transfer of the values will take place (provided that
®
i
Bluetooth is activated and configurated on the receiving device).
i
During transmission, the symbol „
"
flashes in the display. If the transmission
has been sucessful, „OK" appears - if „Err" appears, a transmission error occurred.
®
i
You may transfer the data also later on via Bluetooth manually. Therefore, press
i
and hold START/STOP button
4
when unit is switched off for approx. 5
i
seconds, until the symbol „
" appears. The device will then automatically transmit
all stored values for the actual selected user (
or
).
Discontinuing a measurement
If it is necessary to interrupt a blood pressure measurement for any reason
(eg. the patient feels unwell) the START/STOP button
4
can be pressed at
any time. The device immediately decrease the cuff pressure automatically.
Display stored values
This unit features 2 separate memories, each with a capacity of 120 memory
slots. Results are automatically stored in the memory selected by the user.
Press the MEM button
3
when power off, to call up the measured values
stored. The average values of the last 3 measurements appear on the display.
3
Press the MEM button
again to call up the last measurement value. Repeatedly
8
or
3
pressing the MEM button
displays the respective values measured previously.
If you have reached the final entry and do not press a button, the unit automatically
switches itself off after approximately 8 seconds in memory recall mode. Memory
4
recall mode can be exited at any time by pressing the START/STOP button
which will also switch the unit off. The oldest value is deleted if 120 measured
values have been stored in the memory and a new value is saved.
i
Memory - clear of measurements
If you are sure that you want to permanently remove all stored memories,
press the SET button
5
(when power off) for approximately 3 seconds. Then
5
press SET button
6 more times until CL appears. Press the START/STOP
4
button
and CL will flash for 3 times to clear all memory. Afterwards,
3
press MEM button
and M and "no" will be shown on the display, what
means that no memory is stored anymore.
Error messages and error remedying
Error indicators
appear
G
,
The following symbol will appear on the display when measuring abnormal:
Symbol
Cause
Correction
E-1
Weak signal or
Put on the cuff correctly.
sudden pressure
Repeat the measurement in the
change
correct way.
3
i
E-2
External strong
When near cell phone or other high
disturbance
radiant device, the measurement may
fail.
During measurement, do not move and
do not speak.
E-3
Error during inflation
Put on the cuff correctly. Make sure, that
process
the hose is properly connected.
Repeat the measurement.
3
i
E-5
Abnormal blood
Repeat the measurement after relaxing
pressure
30 minutes.
If you get unusual readings for 3 times,
please contact your doctor.
Weak batteries
The batteries are too low or empty.
Replace all 4 batteries with new 1.5 V
type AAA LR03 batteries.
i
Troubleshooting
i
Problem
Check
Cause and solutions
No power
Check the battery power
Replace all batteries and pay
and if the polarity is
attention to correct polarity
i
correct.
during insertion.
i
No inflation
Check for proper hose
Connect the air hose properly.
i
condition and if it is
properly connected to
Use a new cuff.
the device.
Err appears
Check whether you
Keep your arm and your body
i
and the
have moved the arm
still.
measurement
during inflation or if you
is aborted
have talked during
Do not talk during measure-
i
measurement.
ments.
Leak cuff
Check whether the cuff
Put on the cuff correctly and
is too loose or damaged.
close it tightly. Use a new cuff.
i
Please contact the distributor resp. the service centre if you can't solve the
problem. Do not disassemble the unit by yourself.
on
Cleaning and care
Remove the batteries before cleaning the unit. Clean the unit using a soft cloth
lightly moistened with a mild soapy solution. Never use abrasive cleaning
agents, alcohol, naphta, thinner or gasoline etc.. Never immerse the unit or any
component in water. Be cautiious not to get any moisture in the main unit.
i
Do not wet the cuff or attempt to clean the cuff with water. Using a dry cloth,
gently wipe away any excess moisture that may remain on the cuff. Lay the cuff
flat in an unrolled position and allow the cuff to air dry.
i
Do not expose the unit to direct sunlight; protect it against dirt and moisture.
Do not expose the unit to extreme hot or cold temperatures. Keep the device in
the storage case when not in use. Store the unit in a clean and dry location.
Disposal
This product must not be disposed of together with domestic waste. All users
are obliged to hand in all electrical or electronic devices, regardless of
whether or not they contain toxic substances, at a municipal or commercial
collection point so that they can be disposed of in an environmentally accep-
table manner.
Remove the batteries before disposing of the device/unit. Do not dispose of old
batteries with your household waste, but at a battery collection station at a recyc-
ling site or in a shop. Consult your local authority or your supplier for information
about disposal.
Guidelines / Standards
This blood pressure monitor meets the requirements of the EU standard for non-
invasive blood pressure monitors. It is certified in accordance with EC Guidelines
and carries the CE symbol (conformity symbol) "CE 0297".
The blood pressure monitor corresponds to European standards EN 1060-1 and
EN 1060-3.
The specifications of EU Guideline "93/42/EEC of the Council Directive dated 14
June 1993 concerning medical devices" are met.
Electromagnetic compatibility: (see attached leaflet)
Technical specifications
Name and model
:
MEDISANA Blood pressure monitor BU 530
Display system
:
Digital display
Memory slots
:
2 x 120 measurement values
Measuring method
:
Oscillometric
Power supply
:
6 V=, 4 x 1.5V batteries AAA LR03
Blood pressure measuring range
:
0 – 299 mmHg
Pulse measuring range
:
40 – 199 beats/min.
Maximum error tolerance for
static pressure
:
± 3 mmHg
Maximum error tolerance for
pulse rate
:
± 5 % of the value
Pressure generation
:
Automatic with pump
Deflation
:
Automatic
Automatic switch-off
:
After approx. 3 minutes
,
Operating conditions
:
+5 °C to +40 °C,
15 to 85 % max. relative humidity
Storage conditions
:
-20 °C to +55 °C,
10 to 85 % max. relative humidity
Dimensions (L x W x H)
:
Approx. 149 x 100 x 60 mm
Cuff
:
22 - 36 cm for adults
Weight (main unit)
:
Approx. 333 g without batteries
Item number
:
51174
EAN number
:
40 15588 51174 5
Acessories
:
- Mains adapter
Art. No. 51125 / EAN 40 15588 51125 7
- Cuff M 22 - 36 cm for adults with
average upper arm circumference
Art. No. 51168 / EAN 40 15588 51168 4
- Cuff, L 32 - 42 cm for adults with upper
arm of large circumference
Art. No. 51169 / EAN 40 15588 51169 1
In accordance with our policy of continual product improvement, we
reserve the right to make technical and visual changes without notice.
The current version of this instruction manual can be found under
www.medisana.com
Warranty and repair terms
Please contact your supplier or the service centre in case of a claim under the
warranty. If you have to return the unit, please enclose a copy of your receipt and
state what the defect is.
The following warranty terms apply:
1. The warranty period for MEDISANA products is 3 years from date of purchase.
In case of a warranty claim, the date of purchase has to be proven by means
of the sales receipt or invoice.
2. Defects in material or workmanship will be removed free of charge within the
warranty period.
3. Repairs under warranty do not extend the warranty period either for the unit
or for the replacement parts.
4. The following is excluded under the warranty:
a. All damage which has arisen due to improper treatment, e.g.
nonobservance of the user instructions.
b. All damage which is due to repairs or tampering by the customer or
unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to the
consumer or during transport to the service centre.
d. Accessories which are subject to normal wear and tear as batteries, cuff etc..
5. Liability for direct or indirect consequential losses caused by the unit are
excluded even if the damage to the unit is accepted as a warranty claim.
MEDISANA AG, Jagenbergstr. 19, 41468 NEUSS,
GERMANY.
For service, accessories and spare parts, please contact:
Murrays Health & Beauty
School Lane
Chandlers Ford
Hampshire
UK SO534YN
Tel. +44/2380460600
email: cservices@paulmurrayplc.co.uk

Advertisement

loading