Release
Release mode
Frame advance rate
Self-timer
Remote control modes
(ML-L3)
Exposure
Metering
Metering method
Range (ISO 100, f/1.4 lens,
20 °C/68 °F)
Exposure meter coupling Combined CPU and AI
480
S (single frame), T (continuous low speed),
U (continuous high speed), J (quiet shutter-
release), M (quiet continuous shutter-release),
E (self-timer), V (mirror up)
1–6 fps (T), 6.5 fps (U), or 3 fps (M)
2 s, 5 s, 10 s, 20 s; 1–9 exposures at intervals of
0.5, 1, 2, or 3 s
Delayed remote, quick-response remote,
remote mirror-up
TTL exposure metering using RGB sensor with
approximately 91K (91,000) pixels
• Matrix: 3D color matrix metering III (type G, E,
and D lenses); color matrix metering III (other
CPU lenses); color matrix metering available
with non-CPU lenses if user provides lens data
• Center-weighted: Weight of approximately 75%
given to 12 mm circle in center of frame.
Diameter of circle can be changed to 8, 15, or
20 mm, or weighting can be based on average
of entire frame (non-CPU lenses use 12-mm
circle)
• Spot: Meters 4 mm circle (about 1.5% of frame)
centered on selected focus point (on center
focus point when non-CPU lens is used)
• Highlight-weighted: Available with type G, E, and
D lenses; equivalent to center-weighted when
other lenses are used.
• Matrix, center-weighted, or highlight-weighted
metering: 0–20 EV
• Spot metering: 2–20 EV