PROCEDURE C - REGENERATION OF RESIN IN TOP CHAMBER
Follow manufacturers' insstructions for regeneration of media. Cation exchange resin
may be regenerated in the following manner. NOTE: Due to build up of air pressure, it
is not possible to regenerate both chambers at the same time. Follow steps 1-8 to
regenerate top chamber, then procedure D to regenerate bottom chamber.
1.
3.
Clamp outlet
tube.
5.
Unclamp outlet tube
and allow salt
solution to run to
waste.
7.
9.
At this point the resin in the top chamber should be completely
regenerated.
Prepare salt
solution by
dissolving about
½ pound of salt
(sodium
chloride) in 1
quart of water.
Add salt
solution until
top chamber is
completely
full.
Attach adapter
to faucet.
2.
4.
Allow to stand for about 30
minutes.
6.
8.
Wash resin with
approximately 1
gallon of tap water.
Remove
black plug
from top of
softener.
Clean
threaded area
completely
and replace
black plug in
top of
softener.