Summary of Contents for LaMotte DirectFlo 1026

  • Page 1 DirectFlo water softeners DirectFlo Code 1026 DirectFlo DuoSoft Code 1028...
  • Page 3 INTRODUCTION The DirectFlo and the DirectFLO DuoSoft Water Softeners are designed to produce high quality softened water. The innovative design eliminates cumbersome hoses that must be connected to a faucet. As water passes through the DirectFLO chamber, the resin column causes scale-forming calcium and magnesium ions to be exchanged for non-scale-forming sodium ions.
  • Page 4 PROCEDURE A — Use of the Softeners Lift the plug up about 1”. Turn the large black Turn the plug plug on the top of the counterclockwise softener for 1 full turn to lock counterclockwise it into the upright until it becomes position.
  • Page 5 PROCEDURE B — Replacing the Media in the DirectFlo Softener and the Top Chamber of the DuoSoft Softener. DUOSOFT: Follow steps 1-6 to fi ll the top chamber, then follow PROCEDURE C to fi ll the bottom chamber. Carbon based products are generally used in the top section. Turn the large black Lift the plug up about 1”.
  • Page 6 PROCEDURE C — Replacing the Media in the Bottom Chamber of the DirectFlo DuoSoft Follow steps 1-6 of PROCEDURE B to replace the media in the top chamber of the DirectFlo DuoSoft Softener. Follow the procedure below to replace the media in the bottom chamber.
  • Page 7 PROCEDURE C — continued Replace the plug Turn on the sink in the top of the faucet. Adjust the softener. Turn the water fl ow until plug clockwise the stream is about one complete ¼” in diameter. turn to lock it into the upright position.
  • Page 8 PROCEDURE D — Regeneration of Media in the DirectFlo Softener and the Top Chamber of the DirectFlo DuoSoft Softener Follow manufacturers’ instructions for regeneration of media. Cation exchange resin may be regenerated in the following manner. NOTE: Due to build up of air pressure in the DirectFlo DuoSoft, it is not possible to regenerate both chambers at the same time.
  • Page 9 PROCEDURE D — continued Turn on the sink Close the CLOSED faucet. Adjust the softener water fl ow until valve. the stream is about ¼” in diameter. Place the softener in the sink so that the stream of water hits the top of the softener on the Allow the softener to fi...
  • Page 10 PROCEDURE E — Regeneration of Media in Bottom Chamber of the DirectFlo Softener Follow manufacturers’ instructions for regeneration of media. Cation exchange resin may be regenerated in the following manner. Follow steps 1-8 of PROCEDURE D to regenerate the media in the top chamber of the DirectFlo DuoSoft Softener.
  • Page 11 PROCEDURE E — continued Turn the plug Turn on the sink clockwise faucet. Adjust the one complete water fl ow until turn to lock it the stream is about into the ¼” in diameter. upright position. Place the softener in the sink so that the stream of water hits the top of the softener on the CLOSED...
  • Page 12 PO Box 329 • Chestertown • MD • 21620 800-344-3100 • 410-778-3100 • f 410-778-6394 www.lamotte.com 61026 7.11...