Installation Requirements; Tools; Location Requirements; Opening Dimensions - Whirlpool WUW35X15DS Use & Care Manual

Hide thumbs Also See for WUW35X15DS:
Table of Contents

Advertisement

Available languages

Available languages

Tool Needed
Gather the required tool before starting installation.
Phillips screwdriver

Location Requirements

WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from wine cellar.
Failure to do so can result in death, explosion, or fire.
NOTES:
It is recommended that you do not install the wine cellar near
an oven, radiator, or other heat source.
Do not install in a location where the temperature will fall
below 55°F (13°C). For best performance, do not install the
wine cellar behind a cabinet door or block the base grille.

Opening Dimensions

Height dimensions are shown with the leveling legs extended
to the minimum height.
NOTE: When leveling legs are fully extended, add ⁵⁄₈" (15 mm)
to the height dimensions.
If the floor of the opening is not level with the kitchen floor,
shim the opening to make it level with the kitchen floor.
15" Models
15
/
"
3
4
(40.0 cm)
1
/
"
3
16
(3 cm)
A*
B*
35
/
"-35
B1*
1
4
(89.5-91.0 cm)
WUW35X15DS
WUW55X15DS
C
C
A
B1
B
D
D
NOTE: Door clearance of 10
shelf extension.
4 4 4 4 4 4 4 4 4 4 4 4

INSTALLATION REQUIREMENTS

Tools

Depth Dimensions
24
/
" (63.2 cm) -
7
8
A*
w/o handle
/
"
13
16
26
/
" (67.7 cm) -
5
8
B*
WUW35X15DS
26
/
" (68.2 cm) -
7
8
B1*
WUW55X15DS
A
Dimensions
A
21
/
" (55.5 cm)
7
8
B
25
/
" (64.7 cm)
1
2
B1
25
/
" (65.2 cm)
11
16
C
15" (38.0 cm)
34
/
" - 34
1
16
D
(86.5 cm - 88.0 cm)
/
" (27 cm) required to allow full
5
8
24" Models
24
(62.5 cm)
A*
B*
B1*
WUW35X24DS
C
B
D
NOTE: Door clearance of 16
shelf extension.

Electrical Requirements

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Before you move your wine cellar into its final location, it is
important to make sure you have the proper electrical
connection.
Recommended Grounding Method
A 115 Volt, 60 Hz., AC only, 15– or 20–amp fused, grounded
electrical supply is required. It is recommended that a separate
circuit serving only your wine cellar be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
/
NOTE: Before performing any type of installation, cleaning, or
5
"
8
removing a light bulb, unplug wine cellar or disconnect power.
/
"
5
8
1
/
"
3
16
(3 cm)
35
/
"-35
/
"
1
13
4
16
(89.5-91.0 cm)
WUW55X24DS
C
A
A
B1
D
/
" (41 cm) required to allow full
1
8
WARNING
Electrical Shock Hazard
Depth Dimensions
24
/
" (63.2 cm) -
7
8
A*
w/o handle
26
/
" (67.7 cm) -
5
8
B*
WUW35X24DS
26
/
" (68.2 cm) -
7
8
B1*
WUW55X24DS
Dimensions
A
21
/
" (55.5 cm)
7
8
B
25
/
" (64.7 cm)
1
2
B1
25
/
" (65.2 cm)
11
16
C
23
13
/
" (60.5 cm)
16
34
/
" - 34
/
1
5
"
16
8
D
(86.5 cm - 88.0 cm)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wuw35x24dsWuw55x15dsWuw55x24ds

Table of Contents