Pre-Installation; Features; Venting; Fuel - Lennox RAVL42 Installation And Operation Manual

Direct-vent fireplace
Table of Contents

Advertisement

PRE-INSTALLATION

Features

Installation Options
Residential
Vented vertical and horizontal
Manufactured (mobile) home
Natural gas (NG) or propane (LP)
Bedrooms
Optional wall-mounted or remote thermostat
Ductable for greater heat distribution

Venting

This fireplace can be vented with Security™ Secure Vent™ pipe*. Coaxial
pipe diameters are 6-5/8" outer and 4" inner. The combustion air for this
fireplace is drawn from outside the house through the outer DV (direct-
vent) pipe. Room air is not required for combustion.
When planning your installation, select the correct length of vent pipe
for your particular requirements. Determine the minimum clearance to
combustibles from the rear of the unit to the wall. It is also important
to note the thickness of the wall. Before cutting the vent hole through
the wall make sure that ALL vent and termination clearances (see Pages
18-24) will be met.
Electrical
The standard fan motor requires 120 Volts AC for operation. The fireplace
is not dependent on the fan or an outside electrical supply to operate.
Millivolt Valve
This fireplace is operated with a millivolt valve and therefore burns even
during a power outage.
Max/Min Input BTUh 0-2,000 Feet (0-610 M)u
Manifold Pressure (IN. WC)
Min. Inlet Pressure (IN. WC)
Maximum heat output BTUs/hour-steady state
P4 Efficiency
Orifice (DMS) 0-2,000 Feet (0-610 M)
u
Unit factory equipped for 0-2000 FT/0-610 M, In Canada 0-4500 FT/0-1370 M
v
The Steady State Efficiency numbers based on maximum vent configuration.
w
Tested to CSA P.4.1-02 "Testing Method for Measuring Annual Fireplace Efficiency.
Electrical Rating: 120 VAC, 60 HZ, Less Than 2 Amps
6
RATINGS
w
u

Fuel

This fireplace comes from the factory equipped to burn natural gas at a
specified elevation. The fireplace can be converted to burn LP gas (liquid
propane) by changing the cassette (valve and pilot assembly) or installing a
conversion kit. Only Lennox Hearth Products conversion kits can be used to
convert from NG to LP or LP to NG. Contact your Lennox Hearth Products
dealer for details.

Specifications

Fireplace weight: 250 lbs
Pipe:Type - direct-vent
Recommended manufacturer*
Security™ Secure Vent™*
Diameter - 6-5/8"x 4" for vertical terminations
Diameter - 8"x 5" for horizontal terminations

Packaging List

The Ravelle™ 42 gas fireplace comes with the following parts:
1 Fireplace Body with Burner Cassette
1 Log Set
1 Bag of Ember Material
1 Installation and Operation Manual
Decorative Faces - One Required
Arch Inset
Classic Inset
Screen
Foundry™
Brick Liners - One Required
Standard Brick
Red Brick
Architectural Stone
Note: See Pages 36 and 37 for ordering information.
* Other approved chimney brand is Simpson Dura-Vent DV-GS.
Model Ravelle 42
NATURAL GAS
42,000 / 29,500
3.5 / 1.7
5
34,860
50.43%
#30
Ductability (optional)
Forced Air Duct Kit
Whole Home Comfort
System
LP GAS
36,000 / 25,000
10 / 5.1
11
29,880
53.47%
#49

Hide quick links: