DO NOT re-use compressor oil or any oil that has been
exposed to the atmosphere. Dispose of oil per local codes
and regulations. DO NOT leave refrigerant system open to
air any longer than the actual time required to service the
equipment. Seal circuits being serviced and charge with
dry nitrogen to prevent oil contamination when timely
repairs cannot be completed. Failure to follow these proce-
dures may result in damage to equipment. For information
about replacement oil type and viscosity, see the Mini VRF
Outdoor Unit installation instructions.
UNIT 40WAW
POWER SUPPLY (V-Ph-Hz)
COOLING CAPACITY (Btuh)
HEATING CAPACITY (Btuh)
INDOOR FAN MOTOR
Type
Input (W)
INDOOR COIL
Number of Rows
Fin Spacing (fins/in.)
Fin Type
Tube Diameter, OD (in.)
Tube Type
Number of Circuits
INDOOR AIRFLOW (cfm)
Low
Medium
High
INDOOR NOISE LEVEL (dBA)
Low
Medium
High
UNIT DIMENSIONS (in.)
Width
Height
Depth
PACKING DIMENSIONS (in.)
Width
Height
Depth
NET/GROSS WEIGHT (lb)
REFRIGERANT TYPE
EXPANSION DEVICE
DESIGN PRESSURE, H/L (psig)
REFRIGERANT PIPING (in.)
Liquid Side, OD
Suction Side, OD
CONNECTING WIRING
Power Wiring
Signal Wiring
DRAINAGE WATER PIPE DIAMETER, OD (in.)
LEGEND
EXV
— Electronic Expansion Valve
NEC
— National Electrical Code
The 40WAW high wall mount unit provides an efficient
way to heat or cool a space and an attractive appearance. The
equipment is initially protected under the manufacturer's stan-
dard warranty; however, the warranty is provided under the
condition that the steps outlined in this manual for initial in-
spection, proper installation, regular periodic maintenance, and
everyday operation of the unit be followed in detail. This man-
ual should be fully reviewed in advance before initial installa-
tion, start-up and any maintenance. Contact your local sales
representative or the factory with any questions BEFORE pro-
ceeding.
Table 1 lists physical data for each unit size. See Fig. 1 for
model number nomenclature. Figures 2and 3 show unit dimen-
sions.
Table 1 — 40WAW Physical Data
007
009
7,500
9,500
8,500
10,900
35
3
253
282.5
309
29
32
35
36
1
11
/
2
9
1
40
/
4
15
3
/
8
1
12
/
2
30/37
Sized per NEC and Local Codes Based on Nameplate Electrical Data
2

GENERAL

012
015
208/230-1-60
12,000
15,000
13,600
17,000
AC Motor
2
16
Aluminum with Hydrophilic Coating
9
/
32
Copper Tube with Inner Groove
282.5
370.8
306
444
347
506
R-410A
EXV (Integrated with the Evaporator)
650/250
1
/
4
1
/
2
3-Core Shielded Wire
3
/
4
018
024
19,000
24,000
21,000
27,000
55
100
19
6
444
400
506
518
544
700
34
41
38
42
40
45
1
/
49
1
/
42
4
4
1
3
12
/
12
/
2
4
9
9
5
/
8
1
46
/
53
2
16
3
/
17
8
1
1
12
/
13
/
2
4
35/44
44/55
3
/
8
5
/
8