Stainless Steel Filter Maintenance (Continued)
Sink Cleaning
Remove the Honeycomb Pre-Filter from the Stainless Steel Filter Assembly
and place both components in your sink. Rinse to remove large debris.
Submerge both filters in warm water that contains standard dish washing
soap. Allow the filters to soak for at least 15 minutes, drain the sink and rinse
the filters with cold water.
5. Allow the Stainless Steel Filter and Honeycomb Pre-Filter to dry
completely before inserting them back into the unit. The filter can be
dried in the dishwasher or air-dried. Typically, evaporative air drying can
take 12-24 hours, depending on humidity and temperature.
6. Install the Honeycomb Pre-Filter back into the bottom of the Stainless Steel
Filter Assembly. Don't worry: both ends are the same, so it can be inserted
either way. Never operate the unit without the Honeycomb Pre-Filter.
7. Insert the cleaned and dried Stainless-Steel Filter Assembly back into your
Sharper Image® Ionic Comfort unit. If you have reinstalled the Stainless Steel
Filter Assembly after cleaning and drying, and hear "crackling" after turning
it on, your filter is still wet. Turn the unit off, remove the Filter Assembly and
allow it to dry longer.
NEW 8/15
10
203833-01 and 203833-02

Troubleshooting Guide

Issue:
Resolution:
1. The Filter Assembly needs to be cleaned. Refer to the section on
Stainless Steel Filter Maintenance.
2. Filters are not completely dry after cleaning. Remove the filters
Crackling sound is heard:
from the unit and let them completely dry until the crackling stops.
3. Foreign material is caught between the Stainless Steel Filter
Plates. Turn off and unplug the unit then carefully remove debris
making sure not to bend the plates.
1. After prolonged use, the unit's Ionizer Wire may become dirty.
This may result in poor ion generation and the possibility of a
A "Hissing" sound is heard or;
"Hissing" sound coming from the unit's Ionizer Wire. If this occurs,
Cleaning Performance seems low:
wash the Filter Assembly as described in the section on Stainless
Steel Filter Maintenance.
1. Ensure that the Filter Assembly is properly inserted and the unit
Unit will not Turn On:
is properly plugged into an energized wall outlet.
1. Call Customer Service for a replacement. The unit will not operate
Ionizer Wire is broken:
with a broken Ionizer Wire. Never replace this wire with anything
but approved components supplied by the manufacturer.

Questions and Answers

Questions:
Answer:
The Check Filter LED Indicator illuminates to alert you when the
How often is cleaning of the Stain-
Stainless Steel Filter Assembly needs to be checked for cleaning.
less Steel Filter Assembly required?
It may be necessary to clean the Filter Assembly more frequently
depending on the air quality in your environment.
Can I leave my Sharper Image®
Yes. It is safe and economical to leave on as long as you like - even
Ionic Comfort on continuously?
24 hours per day, 365 days per year.
No. The Sharper Image® Ionic Comfort meets FCC regulations
Will my Sharper Image® Ionic Com-
for harmful interference with radio communications so you may
fort interfere with home or office
place your Sharper Image® Ionic Comfort by your computer, audio
equipment (e.g. computers)?
players, etc. without causing any unusual interference problems.
No. The Stainless Steel Filter Assembly is made of high quality
corrosion resistant stainless steel. Be careful not to bend the plates.
Will the Stainless Steel Filter wear
If the plates touch each other, the electrostatic filtration will be
out over time?
impaired. Note that some phosphate-free dishwasher detergents
can react with aluminum and cause staining. It's recommended to
try water-only cleaning first if washing filter in dishwasher.