Desa GWN6 Installation Manual page 19

Unvented (vent-free) blue flame gas heater
Table of Contents

Advertisement

Available languages

Available languages

WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Fol-
low the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning sup-
plies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc.,
create fumes. These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM
Heater produces unwanted
odors
Heater shuts off in use (ODS
operates)
Gas odor even when control
knob is in OFF position
Gas odor during combustion
Moisture/condensation no-
ticed on windows
117001-01E
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Heater burning vapors from
paint, hair spray, glues, etc.
See IMPORTANT state-
ment above
2. Low fuel supply (propane/
LP gas only)
3. Gas leak. See Warning
statement at top of page
1. Not enough fresh air is
available
2. Low line pressure
3. O D S / p i l o t i s p a r t i a l l y
clogged
1. Gas leak. See Warning
statement at top of page
2. Control valve defective
1. Foreign matter between
control valve and burner
2. Gas leak. See Warning
statement at top of page
1. Not enough combustion/
ventilation air
www.desatech.com
REMEDY
1. Ventilate room. Stop us-
ing odor causing products
while heater is running
2. Refill supply tank
3. Locate and correct all leaks
(see Checking Gas Con-
nections, page 11)
1. Open window and/or door
for ventilation
2. Contact local natural or
propane/LP gas company
3. C l e a n O D S / p i l o t ( s e e
Cleaning and Maintenance,
page 15)
1. Locate and correct all leaks
(see Checking Gas Con-
nections, page 11)
2. Replace control valve
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Con-
nections, page 11)
1. Refer to Air for Combustion
and Ventilation require-
ments (page 5)
19

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Gwn10tGwp10tGwp10Gwn10Gwp6

Table of Contents