FIG. 5:
1200EX
solution inlet filter. Clean
after each use.

SS-P 1200EX

OPERATING INSTRUCTIONS
1. Pre-mix cleaning solution with hot water in a
separate container. Pour mixed solution into the
solution tank of the machine.
IMPORTANT: When necessary use liquid defoamer
agent in the recovery tank to control foaming. Excess
foam in the recovery tank can allow moisture, carpet
fiber and other debris to be drawn through the vacuum
cutoff valve and cause damage to the vacuum motors.
Damage caused by moisture or debris will void the
product warranty. Follow defoamer manufacturer
instructions for proper application.
2. Connect vacuum and solution hoses to machine and
attach to extraction wand or hand tool.
3. If auto-fill operation is desired, attach fresh water
supply to freshwater inlet (Fig. 2, B) and turn on
water supply at faucet. Tank will begin filling and
automatically shut off when full.
4. If auto-pumpout operation is desired, attach a
regular garden hose to recovery tank outlet, and
place other end in suitable drain or large container.
5. Insert both plugs into separate 3-pin grounded
outlets. It is imperative that the cords are plugged
into separate circuits rated for at least 20 amps of
service. Keep cords clear of your cleaning path.
FIG. 7:
(All units)
Vacuum
cutoff valve.
Remove and
rinse clean
after each
use.
24-00265 A 2010-06
6. Switch vacuum control to VAC 1 or VAC 1&2
position.
7. Turn on solution pump.
8. If desired, turn on heater.
9. If using the Auto-Pumpout feature, press the
AutoPumpout switch (Fig. 2, E) to the On position.
10. Begin cleaning. Refer to industry-approved
procedures.
11. Solution pressure may be adjusted with the pressure
regulator knob (Fig. 2, G). Monitor the pressure
gauge to ensure pressure is adequate.
12. When the job is complete, empty and rinse out the
solution tank thoroughly to prevent growth of harmful
bacteria. Turn on both vacuum motors and allow
them to run for 3–5 minutes to help eliminate any
moisture from the vacuum motors and assure long
vacuum life.
For maintenance instructions, see "Maintenance," below.
TIP: To empty the solution tank, remove the vacuum
hose from wand and extract the solution from solution
tank.

MAINTENANCE (ALL UNITS)

WARNING: Unplug machine before
servicing. Possbility of electrical shock.
WARNING: Interior components may be hot
after operation. Let unit cool completely
before servicing.
DAILY OR AFTER EACH USE
Clean vacuum cutoff valve and strainer (Fig. 7).
Empty recovery tank, then open recovery tank lid. Grasp
valve assembly and gently pull downward, taking care
not to distort the strainer screen. Rinse assembly clean
and make sure float ball moves freely inside assembly.
Reinstall securely.
4
FIG. 6:
FIG. 6:
1200EX recovery
1200EX recovery
tank outlet filter.
tank outlet filter.
Rinse screen clean
Rinse screen clean
after each use.
after each use.