Flue System - Keston Heat 45 Installation And Servicing Instructions

Fan powered high efficiency modulating condensing gas boiler
Hide thumbs Also See for Heat 45:
Table of Contents

Advertisement

11 flUe SySteM

iMPoRtAnt
When installing a replacement boiler re-use of existing flue is acceptable if the installer checks and confirms that;
The flue pipe is the approved Marley/Polypipe/Terrain 50mm MuPVC solvent weld flue system.
The flue installation is upgraded to the most recent flue standards taking particular care to comply withe flue in voids.
A risk assessment is conducted to confirm the effectiveness of the flue.
The existing flue will last the lifetime of the new appliance.
deSiGn
Individual air supply and flue outlet pipes are used as standard.
The material used for flue outlet &/or air inlet must be muPVC (PVC-C) to BS 5255 and/or BSEN 1566-1 and BSEN
1329 of an internal diameter of 51mm. (i.e. nominal 50mm diameter muPVC solvent weld waste pipe).
Marley muPVC (PVC-C) Solvent Weld Waste System (50mm) and Polypipe System 2000 muPVC (PVC-C) solvent
weld waste (50mm) are the only systems approved for this application.
The following pipes and fittings are approved:
Polypipe System 2000 muPVC solvent Weld Waste System (50mm)
Poly Pipe Code
MU 301
4m length muPVC wastepipe 5/225
MU 313
50mm x 45 deg muPVC obtuse bend
MU 314
50mm x 92.5 deg muPVC swept bend
MU 310
50mm muPVC straigh coupling
MU 316
50mm x 92.5 deg muPVC swept pipe
Marley muPVC solvent Weld Waste System (50mm)
Marley Code
KP 304
50mm x 4m double spigot pipe
KP32
50mm x 45 deg bend
KSC3
50mm straight coupling
KB3
50mm x 88.5 deg bend
KT3
50mm swept tee
Both the 50mm flue outlet terminal and the 50mm air inlet terminal are supplied with the flue pack and are illustrated in Fig. 1
and must be used in ALL installations. (Both terminals are identical).
Keston Heat -
Installation & Servicing
INSTALLATION
Fig.1
17