Miller Electric Dimension 1000 Owner's Manual page 24

Arc welding power source
Hide thumbs Also See for Dimension 1000:
Table of Contents

Advertisement

D. Sensing Leads Placement Guidelines For Multiple Arcs
Trail
Trail
Work
Clamp
Trail
Trail
OM-2223 Page 20
Remote Voltage
Sense Leads
Remote Voltage
Sense Leads
Lead
Work
Clamp
Lead
Trail
Remote Voltage Sense Leads
Lead
Remote Voltage
Sense Leads
Work
Clamp
Lead
Remote Voltage Sense Leads
Remote Voltage
Sense Leads
Lead
Work
Clamp
Lead
Trail
Lead
BAD
Welding Power
Source
Current flow from lead affects trail
sense.
Current flow from trail affects lead
sense.
Neither sense lead picks up the
Trail
correct work voltage, causing
starting and welding arc instability.
Welding Power
Source
Lead
Welding Power
BETTER
Source
Lead sense is only affected by
weld current from lead.
Trail sense lead is only affected
by weld current from trail.
Due to voltage drops across work
Trail
piece, arc voltage may be low,
causing need for deviation from
Welding Power
standard procedures.
Source
Lead
Welding Power
BEST
Source
Both sense leads are out of the
current paths.
Both sense leads detect arc volt-
age accurately.
No voltage drop between lead and
Trail
trail sense.
Best starts, arcs and most reliable
Welding Power
results.
Source
Ref. 804 108-A