Installing Alternative Plug - Miller Electric 375 Owner's Manual

Air plasma cutter ice-27c torch
Hide thumbs Also See for 375:
Table of Contents

Advertisement

4-9. Installing Alternative Plug

This procedure is necessary if the unit is to be connected to a 230
VAC receptacle, or to a 115 VAC receptacle that requires a plug that
is different from the supplied plug.
See Section 4-8 for instructions on setting changeover switch for
proper voltage.
Tools Needed:
OM-2229 Page 16
6
7
1
1
Cut cord close to plug.
2
2
3
4
5
3
6
7
Strip cord jacket back enough to
separate conductors. Strip conduc-
4
tors enough to make good contact
5
with plug terminals. Make plug con-
nections and reinstall outer shell and
cord grip. Tighten assembly screws
onto shell. Do not overtighten.
Supplied 115 VAC Plug
Alternative Plug (230 VAC
Plug Shown)
Load 1 (Brass) Terminal
Load 2 (Brass) Terminal
Ground (Green) Terminal
Outer Shell
Cord Grip
Ref. 801 305-A / 801 611