ENERGY FIREPLACE INSTALLATION MANUAL AND USER GUIDE
ENERGY FIREPLACES
Aero 3
-SUBJECT TO CHANGE DUE TO IMPROVEMENTS
ENERGY FIREPLACE INSTALLATION MANUAL AND USER GUIDE

3 INSTALLATION

3.1 Place of installation
The fireplace must not be turned upside down or turned to a horizontal
position during transportation.
The fireplace's design allows its installation either in parallel or at an angle
to the wall.
The floor on which your firebox will be mounted must be able to support its
weight as well as the liner that will be fitted on your firebox at a later stage.
The walls around the firebox should be made of fireproof inert materials.
3.2 External air ducts
Since the energy fireplace is a combustion facility inside your living space
and needs to receive air from the area of installation, you have to ensure
that a sufficient supply of clean air is available.
The requirements and the special characteristics of your living space have
to be taken into account before the installation.
The external air duct ensures the exchange of air and oxygen. The
diameter of the air duct should be at least 120mm and the distance
between the air duct and the floor about 100mm. The air duct is very
important for the smooth operation of the fireplace, especially in small
rooms or rooms with insulating frames.
Regal fireboxes with the aero3 system should be connected to two fresh
air ducts of Φ120mm diameter if possible or at least with one duct of the
same diameter. One of the ducts will be inserted into the air motor* and
the other one will be free under the area of the firebox. (An air motor of
450-650m3 air flow is recommended.)
ENERGY FIREPLACES
-SUBJECT TO CHANGE DUE TO IMPROVEMENTS