DISCONNECT THE POWER PLUG BEFORE MAKING ANY TRANSACTION FOR CLEANING AND / OR
MAINTENANCE.
MONTHLY MAINTENANCE
A) DO NOT USE SOAP AND / OR DETERGENTS. (see FIG.1)
B) Clean the water circulation pipes
C) Clean the air filter. THE OPERATION AND 'ABSOLUTELY NECESSARY AS' THE FILTER IS SPORCO
REDUCES UP TO 50% OF THE POWER OF REFRIGERATING MACHINE. (see FIG.2) AND SEE THE
NEXT PAGE IN DETAIL.
D) Clean the display only with a dry cloth (see FIG.3).
E) ABSOLUTELY NOT THE CLEAN MACHINE WITH DIRECT WATER TO WATER AND NOT IMMERSE
(see FIG.4)
F) In case of non-use:
- DISCONNECT THE POWER SOCKET
- Clear CAR Dall'Acqua (see FIG.5)
CLEANING THE FILTER
1) Unscrew the screw nut of the central front (SEE FIG.1).
2) Gently remove the ring (see FIG.2).
3) Unscrew the filter from the front ring (SEE FIG.3 and FIG.4).
4) Remove the ring side (see FIG.5).
5) Unscrew the filter from the side ring (Fig.7 AND SEE FIG.6).
6) Clean the filters with a vacuum cleaner or wash them under running water and dry THEM BEFORE
REASSEMBLING. (See Fig.8)
7) Replace the filters by repeating the previous steps in reverse.
SOLUTION TO SMALL PROBLEMS
PROBLEM: The refrigerator does not work and the display is switched off
--- PROBABLE CAUSE:
A) The refrigerator is turned off
B) Energy inadequate
C) The fuse is broken
--- SOLUTIONS:
A) Turn on the refrigerator
B) Make sure the plug is fully connected to the
C) Replace the fuse
- PROBLEM: The refrigerator is switched on and off at short intervals
--- PROBABLE CAUSE:
A) The voltage is wrong
--- SOLUTIONS:
A) Verify that the voltage is 220 Volts
B) Wait 3 minutes and the machine automatically returns
C) Reset the refrigeration temperature lower than that of the aquarium
- PROBLEM: Reduction and / or lack of refrigeration
--- PROBABLE CAUSE:
A) It is part of the automatic protection
B) The temperature of refrigerated ration temperature is higher than the temperature of the aquarium
C) air filters dirty
D) Lack of gas
--- SOLUTIONS:
A) Wait 3 minutes and the machine automatically returns
B) Reset the refrigeration temperature lower than that of the aquarium
C) Clean the filters
D) To load the machine by an Expert