Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
In Massachusetts a licensed
plumber/gas fitter is required.
This appliance must be installed
with its own shut off valve and the
included gas pressure regulator.
Both the valve and the regulator
must be easily accessible to the
consumer to turn on or shut off the
gas supply after the appliance is
installed.
This appliance and its individual
shut off valve must be disconnected
from the gas supply during any
pressure testing of the system
performed in excess of
(3.5 kPa). The machine must be
isolated from the gas supply line by
closing its individual manual shut off
valve at test pressures equal to or
1
less than
/
psi (3.5 kPa).
2
Any pipe connections must be made
using a thread sealant approved for
gas connections. Failure to correctly
install these items could lead to a
gas leak and subsequent explosion.
1
/
psi
2

Gas connection

The gas connection must be made
in accordance with local codes or in
the absence of local codes with:
-
the National Fuel Gas Code,
ANSI Z 21.1 for the USA
or
-
the current Can / CGA
Interim #58-M95
and .2 Installation Codes for gas
burning appliances for Canada.
Make sure that the maximum gas
supply pressure, before the gas
pressure regulator, is never more than
1
/
psi (3.5 kPa) for natural gas or LP
2
gas.
The minimum supply pressure to get
the required gas input is
6" w.c. for natural gas
10" w.c. for LP gas.