When the lamp run time is
between 3,000 and 4,000
hours, a message may
appear on screen and the lamp
replacement is encouraged.
• NEVER insert your hands into
the ANY opening while AC power
is connected! This could cause
product failure plus severe
personal injury, electric shock
and even death.
• Do not replace the lamp
immediately after the projector
has been used; allow a cooling
period of 1 hour or more before
lamp replacement. The lamp
assembly may still be hot and
can cause burns.
• Do not shake or otherwise
roughly handle the lamp unit.
This may cause failure.
• Do not use any flammable cloth
or duster to clean the internal
parts of the projector. This may
cause a fire.
Usable Lamp Life
• When the "Lamp Power" is set at
"Normal", the lifetime of the lamp
will be approximately 4000 hours.
This is an average lifetime and
cannot be guaranteed.
• The lamp may not reach 4000
hours depending on your viewing
frequency or operating conditions.
• When the lamp has reached the
end of its usable life, deterioration
progresses rapidly.
• If the picture becomes dark,
the tint becomes strange, or the
image flickers, promptly replace
the lamp.

Lamp Replacement Procedure

The lamp is a replaceable item. If the image becomes dark over time, or the lamp fails then
replace the lamp assembly.
1 Remove the Power Plug from the Outlet
2 Remove the Lamp Cover
• Remove the screws with a
3 Loosen the Screws on the Lamp Unit
• Loosen the screws with a
4 Pull Out the Lamp Unit
• Grasp the handle and pull out the lamp unit.
Purchasing the Lamp Unit
Please consult your authorized Wolf Cinema dealer.
Lamp Unit
Part No.: WC-LPU230 [SDC-12 and SDC-15, 2013 models]
WC-LPU220 [SDC-15, pre-2013 production]
SDC-12/SDC-15

Replacing the Lamp

screwdriver.
screwdriver.
Handle
65