Install Crank Handle For High Pressure Hose Reel/Cord Reel; Fill Up Detergent Tanks; Fill Up Tank For Nilfisk-Alto Antistone (Anti-Scale); Antiscale - Nilfisk-ALTO NEPTUNE SB Original Instructions Manual

Hide thumbs Also See for NEPTUNE SB:
Table of Contents

Advertisement

NEPTUNE SB
3.3
Install Crank handle
for high pressure hose
reel/cord reel
3.4

Fill up detergent tanks

3.5
Fill up tank for Nilfisk-
ALTO AntiStone (Anti-
Scale)
3.6

Antiscale

Machine flow L/h
900
900
1000
1000
8
A
The Nilfisk Alto Antiscale dosing
system is set by the factory.
To adjust the water hardness we
recommend that the inlet water
is tested accordingly.
Pump size ml/h
˚dH
35
0-12
35
12-30
35
0-12
35
12-30
1. Pull cap of crank in arrow
direction.
2. Align tabs on crank with slot
in axle.
3. Put crank on axle of high pres-
sure hose reel/cord reel.
4. Fix crank by pushing the cap.
1. Fill up detergent tanks (A) and
(B) with prediluted detergent.
Capacity see chapter 9.4
Technical Data
B
1. Fill up Nilfi sk-ALTO Anti-Stone
(Anti-Scale)/water softener
reservoir with the sample
bottle provided. Nilfi sk-ALTO
AntiStone (Anti-Scale) pre-
vents any deposits of scale
and acts at the same time as
a corrosion inhibitor.
For compatibility reasons, use
only the tested Nilfisk-ALTO
AntiStone (Anti-Scale) which is
available as a six-pack of 1 liter
bottles by ordering part number
8466.
Use the schematic to find the
right dosage of No Scale/anti
stone and water, and add the
mixture to the antiscale tank.
˚f
˚e
0-21,5
0 - 15
21,5 - 53,7
15 - 37,5
0-21,5
0 - 15
21,5 - 53,7
15 - 37,5
Dosage
1:1 = 17ml/h
Pure = 35ml/h
1:1 = 17ml/h
Pure = 35ml/h
1)
Options / model variants
Original instructions

Advertisement

Table of Contents
loading