Manual Mode; Using Cleaning Agents - Nilfisk-ALTO NEPTUNE SB Original Instructions Manual

Hide thumbs Also See for NEPTUNE SB:
Table of Contents

Advertisement

NEPTUNE SB
4.4

Manual mode

4.4.1 Cold water operation /
Hot water operation (up
to 100°C)
4.5

Using cleaning agents

A
CAUTION!
Never allow cleaning agent
to dry on the surface to be
cleaned. The surface may be
damaged.
14
3%
B
5%
ca.
The percentage shown in the
illustration are only approximate
data.
For special applications such as
disinfection, the exact detergent
concentration has to be deter-
mined by using a graduated
measuring container. For water
outlet volume of the machine see
chapter 9.4 technical data.
1%
1%
3%
5%
ca.
1. Turn the main switch to posi-
tion
(cold water).
Control electronics accomplishes
a self check.
The Display shows for approx. 1
second „---".
The motor starts.
is ON.
2. Turn the main switch to posi-
tion
(hot water).
3. Select temperature.
4. Unlock the spray gun and
squeeze trigger.
5. The oil burner will light.
6. Release trigger and lock the
spray gun when not in use.
NOTE!
The cleaner switches off auto-
matically twenty seconds after
the spray gun has been closed. To
start the cleaner again, squeeze
the trigger and the machine will
start automatically.
1. Select desired detergent (A)
or (B) and amount by turning
the knob to desired percent-
age.
2. Spray the object to be cleaned.
3. Allow the cleaning agent to
work, depending on the de-
gree of soiling. Then rinse off
with high pressure.
The use of cleaning agents while
using the steam device will show
a lower percentage and will result
in a lower concentration.
1)
Options / model variants
Original instructions

Advertisement

Table of Contents
loading

Table of Contents