Application Area / Device Features; Application Area; Safety Instructions - oventrop REGTRONIC PE Operating Manual

Microcontroller-controlled temperature difference controller for solar thermal systems
Table of Contents

Advertisement

1

Application area / device features

1.1 Application area

The REGTRONIC PE controllers are high-performance microprocessor-controlled
units for controlling the functions of solar thermal systems. The REGTRONIC PE is
the ideal controller for systems with one collector and one storage tank.
The controllers are designed for use in dry areas and for residential, business and
commercial applications. If you want to use the unit for other purposes, check ap-
plicable statutory regulations before use.
1.2 Device features
The REGTRONIC PE generation of controllers is equipped with the following fea-
tures:
Intuitive user menus with icons and four control buttons
Adjustable control values
RPM control of the solar circuit pump via block modulation or switching controll
Extensive functions for system monitoring, using symbols to indicate errors and
faults
Storage of all values, even during prolonged mains power supply outage
Various protective functions: system and collector protection, recooling and
flow monitoring
Generous wiring space
Available accessories:
Temperature sensor PT1000
Sensor connection box
Immersion sleeves
2

Safety instructions

Always ensure that you isolate the device from the mains power supply before
starting installation or wiring work on its electrical components. Make sure that
you never confuse the SELV (safety extra low voltage) connectors (sensor, flow
transmitter) with the 230 V connectors: this will destroy the device. Life-threat-
ening voltages may be present in both the device and the connected sensors.
Solar power systems can generate high temperatures. There is therefore a risk of
burn injuries! Exercise caution when installing the temperature sensors!
Mount the REGTRONIC PE in a location where it will not be subjected to exces-
sive operating temperatures (>50 °C) by any external heat sources.
For safety reasons, the system should only be operated manually during testing.
In this operating mode, the system does not monitor maximum temperatures or
sensor functions. Do not operate the system if there is recognisable damage to
the controller, cables or the connected pumps and valves.
You must isolate the
control unit from mains
power before carrying out any
assembly or wiring work.
The connection and start-up of
the REGTRONIC PE should only be
carried out by qualified technical
personnel. All work must comply
with the applicable safety
regulations.