Contents Contents Terms you may neeed to know Keypad Lights 3, 4 Keypad Buttons User Functions Fully Arming the System - ON Mode Partially Arming the System - Partial Mode Isolate a section from being Armed System OFF - Disarming the System User Code - Programming Master Code - Programming Other Features...
Terms ..you may need to know Alarm The state of a security system when an armed sensor has been activated. Arming To place a section or panel ready to accept an alarm. Central A place where alarms are received and appropriate action Station taken in response to the Station alarm.
Keypad - Indicators Section Lights- There are 8 or 24 section lights on the command centre. When the system is in the OFF mode all non 24 hour sections are not armed and the Section Lights indicate the condition of the sensor..When the Section Light is On the sensor is activated (e.g.
Page 6
Keypad Indicators ..cont'd Partial Light ON when the Partial mode has been selected and only some of the sections are armed. Single flash when the system is Partially armed and Exit timer is running. Double flash when the system is armed and the Entry timer is running.
Keypad Keys 0 - 9 Keys Used to enter numeric Codes or Function Numbers. Test Key Used when a valid User Code has been entered to enter Test mode. Isolate Key Used when a valid User Code has been entered to Isolate a section, usually before Arming the System.
Fully Arming the System - ON Mode Notes: The system will not change to ON mode unless all section lights are out or isolated. Power light should be ON and not flashing. Program, Fire and Auxillary lights,if fitted, should be out. Exit Timer starts as soon as ON light starts flashing and beeper gives exit warning.
Isola Isola te te te te te a Section from being Armed Isola Isola Isola Notes: When entering section numbers a two digit number eg 01 or a single 1 may be used. Single digit entry. i.e. the leading zero is ignored) Only valid section numbers may be entered.
User Codes User Codes Changing User Codes User Codes User Codes Notes: User 01 default is 1111. User codes are 4 digits long. User codes are used to change the status of the panel, isolate sections or acknowledge alarms. User codes cannot be the same or within one count of another User code including the first 4 digits of the Master Code.
Changing the Master Code Notes: Master code default is 218572. Master code is 6 digits long. The Master code is only used to program the user codes. It cannot change the status of the system. The system must be in OFF mode to enter the master code. Key Sequence Operation Enter existing Master...
Test Functions Notes: Test your system regularly and this will keep you familiar with the system and confident in the system operation. Maximum testing time is 10 minutes. The system must be in OFF mode before entering test mode. Test mode may not be entered until all alarm messages have been transmitted.
W W W W W ar ar ar ar ar r r r r r anty anty anty anty anty Manufactured equipment is warranted to be free from defects in material and wokmanship for a period of 5 years (60) months from the date of manufacture as indicated by the date stamp and/or serial number on the product.
Important Information Control Panel Type Security Company Central Station Phone Date Installed Installed by Emergency Numbers Local Police Fire Brigade Ambulance Doctor page 13...