C. SOUND MODE
Press the MENU button till S1_x or S2_x is shown in the display
S1_x and S2_x are 2 different sound programmes.
With music applied the last number will count up from 0 till 20. These are the steps of the sound programmes.
Press ENTER to confirm and save these settings.
DMX-512 CONNECTION
If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the
first unit in a DMX chain. Always connect the output of one unit with the input of the next unit until all units are connected.
If you use a controller with 5-pin DMX connection, you will need to use a 5-pin to 3-pin adapter.
At the last fixture, the DMX cable has to be terminated. Solder a 120 Ohm resistor between signal (-) and signal
(+) into a 3-pin XLR connector and plug this into the DMX output of the last fixture in the chain.

DMX CHANNELS

Channel
Function
1
Strobe
2
Red
3
Green
4
Blue
5
Rotation
6
Mode

FIXTURE CLEANING

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding
can cause greater accumulation of dirt on the unit's optics.
Make sure the area below the installation place is free from unwanted persons during servicing
Housings, fixations and installations spots( ceiling, truss, suspensions) should be totally free from any deformation
The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is
detected
In order to protect the fixture from overheat the cooling fans (if any) and ventilation openings should be cleaned
monthly.
The interior of the fixture should be cleaned annually using a vacuum cleaner or air-jet.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every month. Clean the internal optics at least every 30/60 days.
 
ATTENTION: We strongly recommend internal cleaning to be carried out by qualified worker!
Value
Description
000-004
No function
005-255
LED Strobe (from slow to fast)
000-255
Dimming 0-100%
000-255
Dimming 0-100%
000-255
Dimming 0-100%
000-127
Forwards
127-255
Backwards
000-010
No function
011-233
Auto mode
234-255
Sound mode