Hitachi CP-X2514WN User Manual page 69

Hide thumbs Also See for CP-X2514WN:
Table of Contents

Advertisement

OPTION menu
Item
SERVICE
(continued)
(continued on next page)
60
SERIAL SETTINGS
Select the serial communication condition for the
CONTROL port.
BAUD RATE
• The BAUD RATE is fixed to 19200bps
and PARITY is fixed NONE when the
COMMUNICATION TYPE is set to OFF (
TRANSMISSION METHOD
COMMUNICATION
Select the transmission method for communication
(continued)
by the NETWORK BRIDGE from the CONTROL
port.
HALF-DUPLEX: This method lets the projector
FULL-DUPLEX: This method lets the projector
• HALF-DUPLEX is selected as the default setting.
• If you select HALF-DUPLEX, check the setting of
the item RESPONSE LIMIT TIME (
Description
4800bps
9600bps
PARITY
NONE
ODD
HALF-DUPLEX
make two way communication, but only one
direction, either transmitting or receiving data, is
allowed at a time.
make two way communication, transmitting and
receiving data at the same time.
19200bps
EVEN
FULL-DUPLEX
61).
38400bps
59).

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Cp-x3014wnCp-x4014wnCp-wx3014wn

Table of Contents