Connecting the cable
Power Cable Specifications
f The power cable is not supplied with air conditioner .
f
- Select the power supply cable in accordance with relevant local and national regulations .
- Wire size must comply with the applicable local and national code .
- Specifications for local wiring power cord and branch wiring are in compliance with local cord .
Model
AC024JXADCH
AC030JXADCH
AC036JXADCH
AC042JXADCH
AC048JXADCH
1 . RLA is based on AHRI 210/240 colling standard condition [Indoor temp . : 26 . 7 °C / 80 °F(DB) / 19 . 4 6 °C /
67 °F(WB), Outdoor temp . : 35 °C / 95 °F(DB)]
NOTE
2 . Voltage tolerance is ± 10 % .
3 . Maxium allowable voltage between phases is 2 % .
Symbols
• RLA : Rated Load Ampere
• FLA : Full Load Ampere
• MCA : Minumum Circuit Ampere (A)
• MOP : Maximum Overcurrent Protective Device (A)
Tightening power terminal
f Connect the cables to the terminal board using the compressed ring terminal .
f
f Use rated cables only .
f
f Connect the cables with driver and wrench that can apply the rated torque to the screws .
f
f Make sure that appropriate tightening torque is applied for cable connection . If the terminal is loose, arc heat may occur
f
and cause fire and if the terminal is connected too firmly, terminal may get damaged .
M4
10 . 4 ~13 . 0 lbf•in
M5
17 . 4 ~26 . 0 lbf•in
14
4way Outdoor_북미향_IM_EN_DB68-05152A-00_CS6.indd 14
Power source
RLA (A)
9 . 0 0
15 . 1 0
208~230V/60Hz
17 . 0 0
17 . 0 0
17 . 0 0
Tightening torque
1 . 2 ~1 . 8 N•m
2 . 0 ~3 . 0 N•m
FLA
FAN1 (A)
FAN2 (A)
0 . 4 8
-
0 . 4 8
-
0 . 4 8
0 . 4 8
0 . 4 8
0 . 4 8
0 . 4 8
0 . 4 8
Communication : F1, F2
1 phase AC power : L1, L2
MCA
MOP
22
20
21 . 8
30
23 . 5
35
23 . 5
35
23 . 5
35
2015-01-05 오후 4:59:59