ACCESSORIES

Before installation, please check to ensure you have the following accessories.
Please note that the diverter and adapters accommodate the vast majority of standard faucets.
If you have a non-standard or custom faucet you may need to locate and purchase
additional parts.
Install Kit (Divertor and adapters)
Diverter / Hose clamps / Adapter

INSTALLATION PROCEDURE

1. ATTACH THE DIVERTER TO YOUR TAP -
Remove the aerator from tap (pliers may be required), and attach diverter valve in its place
(see photo below). There are adapters supplied in case the diverter does not fit your tap.
DO NOT OVERTIGHTEN. If you have leaks at the diverter, use a few wraps of plumber's
Teflon tape which is available at any hardware store for a couple of dollars.
2. ATTACH THE WHITE HOSE TO THE TAP WATER INLET PORT -
First, slide a squeeze clamp over one end of the white hose.
Then attach the white hose, by simply pushing it firmly over the white plastic port labeled
TAP WATER INLET on the bottom of your ionizer. Squeeze the clamp and position it over the
white port.
Installation Tip: Soaking the hose in hot water for 30 seconds will make attaching it very easy.
White hose
13
Accessories
fuse / pH color chart
Reagent / Test tube
White hose
INSTALLATION PROCEDURE
3. ATTACH THE GRAY HOSE TO THE ACIDIC
WATER OUTLET PORT -
First, slide a squeeze clamp over the end of the hose.
Then attach the gray hose to the white plastic port
labeled ACIDIC WATER OUTLET on the bottom of the
ionizer.
Simply push the hose firmly over the white plastic port.
Squeeze the clamp and position it over the white port.
Ensure the opposite end runs into the sink.
4. POSITION YOUR IONIZER -
Ensure it is on a hard and level surface.
A wall mount can be done - there are keyhole slots
on the back for this.
5. ATTACH THE WHITE HOSE TO THE DIVERTER -
Remove the small compression nut on the back of
the diverter (opposite of the lever). Slide the nut over
the opposite end of the white hose you attached to the
TAP WATER INLET port with the threads positioned so
the nut will screw back onto the diverter.
Push the hose firmly onto the nipple.
Firmly screw the compression nut back on.
Do not over tighten.
6. CONNECT THE POWER CORD to an appropriate GFI outlet.
7. INSTALL FLEXIBLE STAINLESS STEEL SPOUT
- Screw this into the threaded port on the top of the ionizer.
Do not over tighten.