Your Control Panel; Description Of Control Panel Features - Emco Tech Neptune Owner's Manual

Water ionizer
Table of Contents

Advertisement

YOUR CONTROL PANEL

CONTROL PANEL
11

DESCRIPTION OF CONTROL PANEL FEATURES

ⓐ pH pH Level 1 to 4 Selection
Use these four buttons to select the output level.
Depressing "1" will produce the lowest level of alkaline pH and "4" will produce the highest.
If you have never consumed alkaline water - do not use a setting higher than 1 to begin with.
Let your body adjust slowly and naturally for 4-7 days, then you may gradually increase the
alkalinity of the water.
ⓑ Filtered
Depressing this button allows you to select purified water (filtered with no change to pH).
ⓒ Cosmetic Button (Also Cleaning Mode)
Depressing this button allows you to select the level of acid water from lowest to highest.
You may also use this button to perform a manual cleaning cycle.
ⓓ pH Level 1 to 4 LED Indicator
The LED is illuminated indicating the level you have selected.
ⓔ Digital Filter Life Indicator
The digital display indicates the filter life / usage with numbers progressing from 0000 - 9999.
When the indicator reaches 9999, it is time to replace your filter.
ⓕ Ion LED
When lit, this indicates that water is being processed in the electrolysis chamber.
ⓖ Low Pressure LED
When lit, this indicates insufficient operating pressure. A beep sound is activated.
Your NEPTUNE should not be operated when low pressure LED due to potential overheating.
ⓗ Hot Water LED
When lit, hot water has been detected passing through your NEPTUNE.
Turn on cold water IMMEDIATELY. Severe filter and electrolysis chamber damage may
occur upon exposure to hot water!