If a message is setup for recording, the record LED will be
blinking and the message location will be displayed on the
Message Number Display, pressing this button will initiate the
recording process. Pressing it again, with the recording in
process, will stop the recording.
Pressing this button with no LEDs blinking and no message on
the Message Number Display will have no effect.
NOTE: Pressing and holding the Start/Stop button during
power up will set the configuration settings to their default
value. Applies to the DLY, PAS, PLY and 9,600 baud rate of
the MacFi-se.
2.3.6. Select Button
This button selects the message for recording or playing.
Depressing this button sequences through the individual
message positions, represented by the Message Number and
Status Display. The Select button may be used during record
setup or to initiate playback mode when the system is idle.
NOTE: Holding the Select Button during message select
causes the message number to increase by tens to expedite
navigating through the 99 messages.
2.3.7. Message Number and Status Display
These two seven segment LED's indicate which message is
selected and provide a variety of status indications for the
MacFi-se. See the table below for an explanation of the different
modes of the display.
18
A single message may be queued more than once. Any activation
issued once the queue is filled will be ignored. A stop command
will stop the message which is currently playing, and when
released, the next message in queue will begin playing.
If multiple inputs are held active and maintained, the system will
play each message sequence once then stop.
Play while active: Upon receiving a maintained input control
signal, the message starts and continues to play for the duration
which the control signal is held active. If the input signal is
removed prior to the end of the message sequence, the system
will immediately stop playing that message.
If the input is sustained after the current sequence has completed,
another sequence will be initiated. If the input is removed during
the delay time after the final message play in the sequence,
another sequence activation will not occur.
If multiple inputs are maintained active while in this mode, the
system will only play the active message of the highest priority
and then repeat. This mode does not support queuing.
Re-Trigger: This mode allows playing messages to be interrupted
by another incoming message, or another activation of the same
message. If a message is currently playing and another message
activation is received, the currently playing message will be
terminated and the new message will be played.
A maintained message activation will only play the sequence one
time and then stop. If multiple inputs are activated at exactly the
same time, only the lower numbered message of the highest
priority will be played. This mode does not support queuing.